{"id":814,"date":"2025-07-31T14:24:09","date_gmt":"2025-07-31T14:24:09","guid":{"rendered":"https:\/\/cardiocases.com\/?page_id=814"},"modified":"2026-02-01T08:27:18","modified_gmt":"2026-02-01T08:27:18","slug":"left-ventricular-pacing-microport","status":"publish","type":"page","link":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/","title":{"rendered":"Left ventricular pacing Microport"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"814\" class=\"elementor elementor-814\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-16f1299 e-con-full e-flex e-con e-parent\" data-id=\"16f1299\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4d92c29 elementor-widget elementor-widget-heading\" data-id=\"4d92c29\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Microport - Stimulation ventriculaire gauche<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f6633a elementor-toc--minimized-on-tablet elementor-widget elementor-widget-table-of-contents\" data-id=\"8f6633a\" data-element_type=\"widget\" data-settings=\"{&quot;headings_by_tags&quot;:[&quot;h3&quot;,&quot;h4&quot;,&quot;h5&quot;],&quot;exclude_headings_by_selector&quot;:[],&quot;no_headings_message&quot;:&quot;No headings were found on this page.&quot;,&quot;marker_view&quot;:&quot;bullets&quot;,&quot;icon&quot;:{&quot;value&quot;:&quot;fas fa-circle&quot;,&quot;library&quot;:&quot;fa-solid&quot;,&quot;rendered_tag&quot;:&quot;&lt;svg class=\\&quot;e-font-icon-svg e-fas-circle\\&quot; viewBox=\\&quot;0 0 512 512\\&quot; xmlns=\\&quot;http:\\\/\\\/www.w3.org\\\/2000\\\/svg\\&quot;&gt;&lt;path d=\\&quot;M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\\&quot;&gt;&lt;\\\/path&gt;&lt;\\\/svg&gt;&quot;},&quot;minimize_box&quot;:&quot;yes&quot;,&quot;minimized_on&quot;:&quot;tablet&quot;,&quot;hierarchical_view&quot;:&quot;yes&quot;,&quot;min_height&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"table-of-contents.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__header\">\n\t\t\t\t\t\t<h4 class=\"elementor-toc__header-title\">\n\t\t\t\tG\u00e9n\u00e9ralit\u00e9s\t\t\t<\/h4>\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--expand\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__8f6633a\" aria-expanded=\"true\" aria-label=\"Ouvrir la table des mati\u00e8res\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/div>\n\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--collapse\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__8f6633a\" aria-expanded=\"true\" aria-label=\"Fermer la table des mati\u00e8res\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<div id=\"elementor-toc__8f6633a\" class=\"elementor-toc__body\">\n\t\t\t<div class=\"elementor-toc__spinner-container\">\n\t\t\t\t<svg class=\"elementor-toc__spinner eicon-animation-spin e-font-icon-svg e-eicon-loading\" aria-hidden=\"true\" viewbox=\"0 0 1000 1000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M500 975V858C696 858 858 696 858 500S696 142 500 142 142 304 142 500H25C25 237 238 25 500 25S975 237 975 500 763 975 500 975Z\"><\/path><\/svg>\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ff3a5a4 elementor-widget elementor-widget-heading\" data-id=\"ff3a5a4\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Informations g\u00e9n\u00e9rales<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3dc7c1d elementor-widget elementor-widget-text-editor\" data-id=\"3dc7c1d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p class=\"rtejustify\"><strong>Configuration de la stimulation du ventricule gauche<\/strong><\/p><p class=\"rtejustify\">Les diff\u00e9rentes options de programmation peuvent permettre de s\u00e9lectionner une polarit\u00e9 de stimulation ventriculaire gauche qui assure une capture effective et permanente, sans stimulation du nerf phr\u00e9nique, tout en limitant l\u2019\u00e9nergie utilis\u00e9e afin d\u2019accro\u00eetre la long\u00e9vit\u00e9 du dispositif. L\u2019ajustement de l\u2019amplitude de stimulation doit donc permettre d\u2019optimiser la dur\u00e9e de vie du dispositif tout en maintenant une marge de s\u00e9curit\u00e9 suffisante. Les seuils de stimulation ventriculaire gauche \u00e9picardique sont souvent plus \u00e9lev\u00e9s et plus variables que les seuils de stimulation ventriculaire droit. Une \u00e9tude retrouvait des valeurs de seuil 2 fois plus \u00e9lev\u00e9es pour les sondes ventriculaires gauches que pour les sondes ventriculaires droites. Il n\u2019est pas toujours n\u00e9cessaire de respecter une marge correspondant \u00e0 2 fois le seuil car cela s\u2019accompagne d\u2019une usure pr\u00e9matur\u00e9e en cas de seuil d\u00e9passant 2 Volts. Chez certains patients il est n\u00e9cessaire d\u2019ajuster au plus pr\u00e8s l\u2019amplitude de stimulation et la dur\u00e9e d\u2019impulsion de fa\u00e7on \u00e0 obtenir une capture ventriculaire gauche sans stimulation phr\u00e9nique. L'influence de la configuration de stimulation ventriculaire gauche sur le degr\u00e9 de r\u00e9ponse \u00e0 la resynchronisation reste encore \u00e0 d\u00e9finir et constitue tr\u00e8s rarement le crit\u00e8re de choix.<\/p><p class=\"rtejustify\">L\u2019arsenal des sondes ventriculaires gauches propos\u00e9es par les diff\u00e9rentes soci\u00e9t\u00e9s inclut des sondes monopolaires, bipolaires et quadripolaires. La polarit\u00e9 de stimulation est programmable dans le ventricule gauche en utilisant des s\u00e9lections diff\u00e9rentes selon que le dispositif prenne en charge ou non une sonde de stimulation VG quadripolaire (4 \u00e9lectrodes) ou non quadripolaire (1 ou 2 \u00e9lectrodes).\n\nSi une sonde ventriculaire gauche unipolaire est implant\u00e9e, une seule configuration (extr\u00e9mit\u00e9 VG\/bague VD ou co\u00efl VD) peut \u00eatre programmable en fonction des constructeurs et des dispositifs. Pour une majorit\u00e9 de d\u00e9fibrillateurs, le co\u00efl VD est utilis\u00e9 (et pas la bague VD). Pour les stimulateurs, la bague VD (\u00e9lectrode proximale d'une sonde bipolaire) est utilis\u00e9e. Pour certains dispositifs et en fonction des constructeurs, le boitier peut faire partie du vecteur de stimulation permettant une seconde option de programmation (extr\u00e9mit\u00e9 VG\/boitier).\n\nSi une sonde ventriculaire gauche bipolaire est implant\u00e9e, entre 3 et 6 configurations sont disponibles en fonction des constructeurs et des dispositifs. Les seuils sont souvent plus \u00e9lev\u00e9s pour la configuration Anode VG\/Spire VD et l\u2019\u00e9lectrode ventriculaire gauche distale (cathode) est pr\u00e9f\u00e9rentiellement utilis\u00e9e comme \u00e9lectrode active, la spire VD ou la bague VG (anode) \u00e9tant utilis\u00e9e comme \u00e9lectrode neutre.\n\nSi une sonde ventriculaire gauche quadripolaire est implant\u00e9e, entre 12 et 17 configurations sont disponibles en fonction des constructeurs et des dispositifs. Cette multitude d'options permet d'optimiser le choix en fonction des crit\u00e8res de seuil et d'absence de stimulation phr\u00e9nique. Les \u00e9lectrodes \u00e9tant \u00e9galement consid\u00e9rablement espac\u00e9es, il est \u00e9galement possible d'obtenir une s\u00e9quence d'activation diff\u00e9rente en fonction que l'on choisisse par exemple une \u00e9lectrode distale (apicale) ou proximale (basale). Il parait \u00e9vident que ce choix aura donc une influence nette sur le degr\u00e9 de r\u00e9ponse m\u00eame si nous sommes encore d\u00e9pourvus en termes de crit\u00e8res permettant de pr\u00e9dire de fa\u00e7on objective la qualit\u00e9 de la r\u00e9ponse future. Seuls les dispositifs Abbott permettent aujourd'hui le choix d'une stimulation double site ventriculaire gauche, l'augmentation du nombre de sites ayant \u00e9t\u00e9 propos\u00e9s comme une solution pour r\u00e9duire l'asynchronisme d'activation.\u00a0<em>sonde LV unipolaire<\/em>\u00a0est implant\u00e9, une configuration unique (pointe LV vers anneau RV ou bobine RV) peut \u00eatre programm\u00e9e en fonction du fabricant et du type d'appareil. Avec la plupart des d\u00e9fibrillateurs, la bobine RV est utilis\u00e9e \u00e0 la place de l'anneau RV.  Avec certains appareils et, selon le fabricant, le g\u00e9n\u00e9rateur d'impulsions peut participer au vecteur de stimulation, offrant la programmation de la pointe LV \u00e0 g\u00e9n\u00e9rateur d'impulsions (can) comme second choix de configuration de stimulation.  Le seuil est souvent plus \u00e9lev\u00e9 avec la configuration anneau LV-bobine RV et l'\u00e9lectrode LV distale (cathode) est pr\u00e9f\u00e9rentiellement utilis\u00e9e comme \u00e9lectrode active, tandis que la bobine RV ou l'anneau LV (anode) sont utilis\u00e9s comme \u00e9lectrode indiff\u00e9rente. Si une sonde LV quadripolaire est implant\u00e9e, entre 12 et 17 configurations sont disponibles en fonction du fabricant et du type de dispositif. Cette multitude de choix permet d'optimiser le seuil de capture et de r\u00e9duire la probabilit\u00e9 de stimulation du nerf phr\u00e9nique. Avec un large espacement des \u00e9lectrodes, la s\u00e9quence d'activation peut \u00eatre modifi\u00e9e, par exemple en choisissant une \u00e9lectrode distale (apicale) par rapport \u00e0 une \u00e9lectrode proximale (basale). Ce choix peut avoir un impact positif sur le taux de r\u00e9ponse, malgr\u00e9 le manque de crit\u00e8res objectivement pr\u00e9dictifs de la qualit\u00e9 de la r\u00e9ponse au traitement. Aujourd'hui, la plupart des appareils de TRC offrent le choix d'une stimulation LV \u00e0 deux sites, avec l'id\u00e9e qu'une augmentation du nombre de sites stimul\u00e9s diminue encore la dyssynchronie d'activation. Cette id\u00e9e n'a jamais \u00e9t\u00e9 prouv\u00e9e par des essais cliniques randomis\u00e9s multicentriques.<\/p><p class=\"rtejustify\"><strong>Capture anodale<\/strong><\/p><p class=\"rtejustify\">L\u2019amplitude de stimulation influe \u00e9galement sur la probabilit\u00e9 de capture anodique. La cathode situ\u00e9e \u00e0 l\u2019extr\u00e9mit\u00e9 de la sonde ventriculaire gauche est g\u00e9n\u00e9ralement plus petite que l\u2019anode. La taille r\u00e9duite de la cathode explique l\u2019existence d\u2019une haute densit\u00e9 de courant. L\u2019existence d\u2019amplitudes \u00e9lev\u00e9es de stimulation peut r\u00e9sulter en une densit\u00e9 de courant suffisamment \u00e9lev\u00e9e pour capturer le tissu \u00e0 proximit\u00e9 de l\u2019anode. Dans un stimulateur triple chambre, la bague VD est souvent utilis\u00e9e comme anode pour la stimulation VG. Une stimulation \u00e0 haute amplitude peut engendrer l\u2019existence d\u2019une capture anodique ventriculaire droite r\u00e9sultant en une stimulation triple-points : cathode ventriculaire gauche et ventriculaire droite + anode ventriculaire droite. La survenue d\u2019une capture anodique est plus fr\u00e9quente quand la configuration de stimulation VG inclut une vraie sonde bipolaire ventriculaire droite (bague de la sonde) plut\u00f4t qu\u2019une sonde bipolaire int\u00e9gr\u00e9e (l\u2019anode \u00e9tant le co\u00efl distal) probablement parce que la taille de la bague est plus petite permettant une densit\u00e9 de courant plus importante. L\u2019aspect \u00e9lectrocardiographique est souvent l\u00e9g\u00e8rement modifi\u00e9 par rapport \u00e0 l\u2019aspect biventriculaire traditionnel. Un \u00e9lectrocardiogramme 12 d\u00e9rivations, plut\u00f4t qu\u2019une d\u00e9rivation unique du programmateur, est g\u00e9n\u00e9ralement n\u00e9cessaire pour faire le diagnostic. En revanche, une capture anodique peut modifier sensiblement l\u2019analyse des trac\u00e9s lors de la r\u00e9alisation du test de seuil ventriculaire gauche. L\u2019effet h\u00e9modynamique de ce type de stimulation qui consiste \u00e0 augmenter le nombre de sites de stimulation pourrait \u00eatre favorable. L\u2019impact clinique reste \u00e0 d\u00e9montrer. Cette capture anodique requiert g\u00e9n\u00e9ralement des amplitudes de stimulation \u00e9lev\u00e9es ce qui a un effet d\u00e9favorable sur la dur\u00e9e de vie du dispositif.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-98752be elementor-widget elementor-widget-heading\" data-id=\"98752be\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Test de la d\u00e9rivation BT<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e12e1e elementor-widget elementor-widget-text-editor\" data-id=\"6e12e1e\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Le test d'une sonde implant\u00e9e comprend l'analyse de l'imp\u00e9dance, du seuil et des capacit\u00e9s de d\u00e9tection, en les comparant aux valeurs enregistr\u00e9es pr\u00e9c\u00e9demment. Il n'en va pas diff\u00e9remment pour la sonde LV, \u00e0 l'exception de la d\u00e9tection, car la sonde LV n'est pas utilis\u00e9e pour la d\u00e9tection dans les dispositifs MicroPort (uniquement dans les dispositifs CRT de Biotronik et de Boston Scientific).<\/p><p><strong>Test de seuil ventriculaire gauche<\/strong><\/p><p>Le test est tr\u00e8s similaire au test de seuil de la d\u00e9rivation RV, il est lanc\u00e9 en mode DOO avec une sortie de d\u00e9part (3,5 V dans l'exemple) qui diminue par pas de 0,25 V jusqu'\u00e0 la derni\u00e8re valeur de 0,25 V. Comme pour le test de seuil RV, la vitesse de test est de 90 bpm \u00e0 la polarit\u00e9 programm\u00e9e (pointe LV vers bobine RV dans ce cas) et \u00e0 la largeur d'impulsion (0,35 ms par d\u00e9faut). Une fois le test effectu\u00e9, le trac\u00e9 est gel\u00e9 et il est possible de r\u00e9analyser l'EGM. Les valeurs seuils s\u00e9lectionn\u00e9es sont les derni\u00e8res valeurs d'amplitude (Volt) qui ont captur\u00e9 le LV. Cliquez sur la sortie de stimulation correspondante ou s\u00e9lectionnez-la \u00e0 l'aide des touches fl\u00e9ch\u00e9es droite ou gauche du clavier (barre bleue dans la figure ci-dessous). Il est n\u00e9cessaire de sauvegarder les r\u00e9sultats apr\u00e8s chaque test, ceux-ci \u00e9tant report\u00e9s dans le tableau de l'assistant de test et dans le tableau \u00ab Leads \u00bb de l'\u00e9cran \u00ab Summary \u00bb. Voir des exemples en direct de tests de seuils BT dans <a href=\"https:\/\/microportacademycrm.com\/courses\/crt-interrogation\/\">nos vid\u00e9os d'interrogatoire<\/a>. Apr\u00e8s le test de seuil LV, le seuil de stimulation du nerf phr\u00e9nique peut \u00eatre enregistr\u00e9 (le cas \u00e9ch\u00e9ant) avec le seuil de stimulation gauche. Lorsque la stimulation multipoint est activ\u00e9e, le test de stimulation est divis\u00e9 en LV MP1 et LV MP2 comme programm\u00e9. Cependant, la stimulation multipoint (stimulation du ventricule gauche sur plusieurs sites) n'est actuellement pas recommand\u00e9e car elle consomme plus d'\u00e9nergie et ses avantages n'ont pas encore \u00e9t\u00e9 d\u00e9montr\u00e9s.<\/p><p><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p27.jpg\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-24381 size-large\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p27-1024x691.jpg\" alt=\"\" width=\"625\" height=\"422\" \/><\/a><\/p><p style=\"text-align: center;\"><strong>Dans cet exemple, le seuil de stimulation de la pointe du ventricule gauche \u00e0 la bobine du ventricule gauche est de 1,25 V. Il n'y a pas eu de stimulation du nerf phr\u00e9nique (SNP), l'option SNP \u201cNon\u201d a \u00e9t\u00e9 s\u00e9lectionn\u00e9e mais elle n'est pas obligatoire, elle appara\u00eetra vide dans la liste si rien n'est sauvegard\u00e9. Cependant, il est important de sauvegarder la valeur \u00e0 laquelle la stimulation du nerf phr\u00e9nique se produit, car cela facilite la s\u00e9lection du meilleur vecteur.\u00a0<\/strong><\/p><p><strong>Vecteurs de stimulation LV<\/strong><\/p><p>L'onglet suivant de l'\u00e9cran des tests est \u00ab LV Vectors \u00bb. L'assistant affiche : dans le tableau \u00e0 gauche de l'\u00e9cran, les derni\u00e8res mesures d'imp\u00e9dance pour chaque vecteur, le seuil de stimulation LV et le seuil de stimulation du nerf phr\u00e9nique (PNS), et \u00e0 droite de l'\u00e9cran, le(s) vecteur(s) LV et les param\u00e8tres de stimulation LV qui sont actuellement programm\u00e9s. Il suffit de cocher dans le tableau de gauche les vecteurs que vous souhaitez tester, de choisir la fr\u00e9quence de test, puis de cliquer sur \u00ab LV test : Start \u00bb pour commencer. L'\u00e9cran de test de seuil s'ouvre et cliquez sur start pour lancer le test. Les seuils de stimulation et \u00e9ventuellement de nerf phr\u00e9nique sont enregistr\u00e9s, puis cliquez sur le bouton \u00ab NEXT \u00bb pour tester le vecteur suivant et ainsi de suite. A la fin des tests, l'\u00e9cran LV Vectors affiche les r\u00e9sultats. Vous pouvez alors s\u00e9lectionner le(s) vecteur(s) que vous souhaitez programmer, puis cliquer sur \u00ab Apply \u00bb et afficher l'\u00e9cran des param\u00e8tres de Brady. Les valeurs s\u00e9lectionn\u00e9es apparaissent en jaune. Cliquez sur le bouton \u00ab Prog \u00bb pour programmer la s\u00e9lection.<\/p><h2><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p28.jpg\"><img decoding=\"async\" class=\"aligncenter wp-image-24383 size-large\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p28-1024x768.jpg\" alt=\"\" width=\"625\" height=\"469\" \/><\/a><\/h2><p style=\"text-align: center;\"><strong>L'\u00e9cran des vecteurs LV permet un aper\u00e7u rapide des imp\u00e9dances, des seuils de stimulation LV et des seuils de stimulation du nerf phr\u00e9nique (PNS). Plusieurs vecteurs peuvent \u00eatre s\u00e9lectionn\u00e9s et test\u00e9s semi-automatiquement un par un.\u00a0<\/strong><\/p><p><strong>Onglet AGE<\/strong><\/p><p>Le dernier onglet, \u00ab LV Vectors \u00bb, permet de visualiser simultan\u00e9ment les EGM, les marqueurs et l'ECG de l'oreillette et du VR. Ceci peut \u00eatre utilis\u00e9 comme une v\u00e9rification finale que tout fonctionne correctement, en excluant les probl\u00e8mes intermittents de capture RV\/LV et en \u00e9valuant la pr\u00e9sence d'extrasystoles qui peuvent diminuer le %CRT.<\/p><p><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p31.jpg\"><img decoding=\"async\" class=\"aligncenter wp-image-24384 size-large\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p31-1024x691.jpg\" alt=\"\" width=\"625\" height=\"422\" \/><\/a><\/p><p style=\"text-align: center;\"><strong>L'\u00e9cran EGM montre exclusivement des marqueurs As-Bv, l'ECG est \u00e9galement stable.\u00a0<\/strong><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d330477 elementor-widget elementor-widget-heading\" data-id=\"d330477\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Seuil LV automatis\u00e9<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-794ced0 elementor-widget elementor-widget-text-editor\" data-id=\"794ced0\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p class=\"rtejustify\">La fonction du seuil LV automatis\u00e9 est souvent tr\u00e8s proche de <a href=\"https:\/\/microportacademycrm.com\/courses\/5-pacing-and-sensing\/lessons\/stimulation\/topic\/ventricular-autothreshold-algorithm\/\">qui a \u00e9t\u00e9 d\u00e9crite pour le chef de file de la VR<\/a>. La mesure du seuil est bas\u00e9e sur l'analyse de la r\u00e9ponse \u00e9voqu\u00e9e ou sur l'observation de la synchronisation des \u00e9v\u00e9nements RV d\u00e9tect\u00e9s apr\u00e8s un \u00e9v\u00e9nement LV stimul\u00e9. Le seuil est mesur\u00e9 \u00e0 intervalles r\u00e9guliers, selon le fabricant, apr\u00e8s quoi une marge de s\u00e9curit\u00e9 est programm\u00e9e, sans autre v\u00e9rification cycle par cycle de la capture. Il convient de noter que les dispositifs Microport \u00e0 double et triple chambre ne v\u00e9rifient pas la capture cycle par cycle de la sonde LV ou RV.<\/p><p><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/09\/LVAT.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-24045 size-full\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/09\/LVAT.jpg\" alt=\"\" width=\"803\" height=\"477\" \/><\/a><\/p><p>Exemple de test de stimulation LV automatique. La stimulation du ventricule gauche est effectu\u00e9e avec une sortie de stimulation d\u00e9croissante jusqu'\u00e0 ce qu'il y ait un changement clair dans le complexe QRS sur le canal du champ lointain. L'appareil reconna\u00eet une perte de capture et enregistre la sortie de stimulation pr\u00e9c\u00e9dente (0,75 V dans ce cas) comme seuil de stimulation LV.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2bc07b7 elementor-widget elementor-widget-heading\" data-id=\"2bc07b7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Programmation de la d\u00e9rivation LV<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-78f9a06 elementor-widget elementor-widget-text-editor\" data-id=\"78f9a06\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Le bouton \u00ab Param. \u00bb dans la barre de fonction en bas de l'\u00e9cran du programmateur permet d'acc\u00e9der aux param\u00e8tres de programmation de la bradycardie, de la tachycardie et de la t\u00e9l\u00e9surveillance. Le premier \u00e9cran qui appara\u00eet est celui des param\u00e8tres de stimulation antibradycardique, dont la plupart sont d\u00e9crits dans les cours correspondants sur les stimulateurs cardiaques. Nous aborderons les param\u00e8tres de stimulation sp\u00e9cifiques \u00e0 la CRT.<\/p><p><strong>\u00ab Onglet \u00bb SonR CRT Optimisation<\/strong><\/p><p>Dans la section \u00ab SonR \u00bb, on trouve le param\u00e8tre \u00ab SonR CRT optimisation \u00bb avec 4 options possibles : \u00ab Off \u00bb, \u00ab Monitor \u00bb pour lequel l'algorithme traite les donn\u00e9es et propose des valeurs optimales, \u00ab AV \u00bb qui reprogramme automatiquement les d\u00e9lais AV, et \u00ab AV + VV \u00bb qui reprogramme automatiquement les d\u00e9lais AV et les intervalles VV. Pour en savoir plus sur SonR<a href=\"https:\/\/microportacademycrm.com\/courses\/av-vv-optimization\/\"> le cours d'optimisation AV\/VV<\/a>.<\/p><p><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/SonR_screen.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-30602 size-full\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/SonR_screen.png\" alt=\"\" width=\"800\" height=\"601\" \/><\/a><\/p><p><strong>\u00ab Onglet \u00bb V Chambers\/VV delay<\/strong><\/p><p>Dans la section \u00ab Pacing\/Sensing \u00bb, on trouve le param\u00e8tre \u00ab V Chambers\/VV Delay \u00bb. Il permet de choisir monoRV (\u00ab R \u00bb), monoLV (\u00ab L \u00bb), biV (\u00ab R + L \u00bb ou \u00ab L + R \u00bb pacing, d\u00e9finissant l'ordre d'apparition des pics de stimulation ventriculaire si un intervalle VV diff\u00e9rent de 0 est appliqu\u00e9). Le d\u00e9lai VV est choisi entre 0 et 64 ms par incr\u00e9ments de 8 ms.<\/p><p><strong>\u00ab Stimulation LV multipoint (MP) \u00bb Tab<\/strong><\/p><p>Le param\u00e8tre \u00ab Multipoint LV pacing (MP) \u00bb peut \u00eatre utilis\u00e9 si une sonde ventriculaire gauche quadripolaire est implant\u00e9e. \u00abOff \u00bb signifie qu'une seule \u00e9lectrode est utilis\u00e9e comme cathode sur la sonde LV, c'est-\u00e0-dire que le ventricule gauche n'est stimul\u00e9 que sur un seul site. \u00abOn\u00bb signifie que deux \u00e9lectrodes LV sont utilis\u00e9es comme cathodes sur la sonde LV, ce qui permet de stimuler le ventricule gauche sur deux sites distincts. Lorsqu'une sonde quadripolaire est implant\u00e9e, 14 vecteurs de stimulation sont disponibles pour la polarit\u00e9 de stimulation.<\/p><p>Entre 2010 et 2020, de nombreuses \u00e9tudes ont \u00e9t\u00e9 men\u00e9es sur les effets b\u00e9n\u00e9fiques potentiels de la stimulation MP, mais les r\u00e9sultats \u00e9taient controvers\u00e9s. L'id\u00e9e est qu'en ajoutant une deuxi\u00e8me zone de capture du ventricule gauche, ce dernier est activ\u00e9 plus rapidement, ce qui optimise la TRC. Bien que cela soit techniquement vrai, les effets b\u00e9n\u00e9fiques sur la fonction de pompe du ventricule gauche sont tr\u00e8s controvers\u00e9s. En outre, la stimulation multipoint fait plus que doubler la puissance de stimulation du ventricule gauche, ce qui vide la batterie plus rapidement. Les directives actuelles de l'ESC sur la stimulation et la TRC ne recommandent pas la stimulation multipoint.<\/p><p><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/Multipoint_OFF.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-30604 size-full\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/Multipoint_OFF.png\" alt=\"\" width=\"804\" height=\"600\" \/><\/a><\/p><p><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/Multipoint_ON.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-30605 size-full\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/Multipoint_ON.png\" alt=\"\" width=\"802\" height=\"602\" \/><\/a><\/p><p style=\"text-align: center;\"><strong>Lorsque l'on clique sur \u00ab On \u00bb dans l'onglet \u00ab Multipoint LV pacing (MP) \u00bb, deux \u00e9lectrodes de d\u00e9rivation LV sont alors utilis\u00e9es comme cathodes sur la d\u00e9rivation LV, les polarit\u00e9s, l'amplitude et la largeur de stimulation LV respectives pour chacun des dip\u00f4les de stimulation LV \u00ab MP1 \u00bb et \u00ab MP2 \u00bb s'affichant \u00e0 l'\u00e9cran.<\/strong><\/p><p><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/Multipoint_ON_programming.png\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-30606 size-full\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/Multipoint_ON_programming.png\" alt=\"\" width=\"799\" height=\"600\" \/><\/a><\/p><p style=\"text-align: center;\"><strong>En cliquant sur l'un des onglets \u00ab LV pacing polarity \u00bb, un nouvel \u00e9cran s'ouvre permettant de s\u00e9lectionner les \u00e9lectrodes de stimulation LV \u00e0 l'aide d'un sch\u00e9ma.  Si vous souhaitez programmer, en cliquant sur \u00ab Apply \u00bb, vous revenez \u00e0 l'\u00e9cran des param\u00e8tres de stimulation permettant la programmation de la s\u00e9lection effectu\u00e9e.<\/strong><\/p><p><strong>Tachy tab<\/strong><\/p><p>Sous l'onglet tachy, les param\u00e8tres du DAI peuvent \u00eatre programm\u00e9s. <a href=\"https:\/\/microportacademycrm.com\/icd-courses\/\">dans les cours de la CIM<\/a>. Dans les appareils CRT, il est possible de choisir la configuration de stimulation ventriculaire pour les ATP, qui est ind\u00e9pendante de la stimulation : \u00abR \u00bb pour RV, \u00ab L \u00bb pour LV, \u00ab R+L \u00bb pour biV. Le d\u00e9lai VV est forc\u00e9 \u00e0 0 ms lors d'une ATP biV. Il est recommand\u00e9 de conserver ce r\u00e9glage sur \u201c R+L \u201d car la litt\u00e9rature indique qu'il est plus efficace. Si vous souhaitez en savoir plus sur l'ATP, nous vous recommandons vivement de consulter le site suivant <a href=\"https:\/\/www.youtube.com\/watch?v=cM2DAFdNeX0\">cette vid\u00e9o du Dr Josh Cooper<\/a>.<\/p><p><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p65.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-24403 size-large\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p65-1024x768.jpg\" alt=\"\" width=\"625\" height=\"469\" \/><\/a><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Microport &#8211; Left ventricular pacing Content General information Configuration of left ventricular stimulation The various programming options available enable the selection of a LV stimulation polarity associated with a reliable and durable myocardial capture with the least amount of power necessary in order to maximize the longevity of the device, without stimulating the phrenic nerve. [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"parent":53,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-814","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Microport CRM CRT Left Ventricular Pacing | Cardiocases<\/title>\n<meta name=\"description\" content=\"Microport CRM CRT left ventricular pacing \u2014 LV programming, output optimization &amp; real ECG tracings.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Microport CRM CRT Left Ventricular Pacing | Cardiocases\" \/>\n<meta property=\"og:description\" content=\"Microport CRM CRT left ventricular pacing \u2014 LV programming, output optimization &amp; real ECG tracings.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/\" \/>\n<meta property=\"og:site_name\" content=\"Cardiocases\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-01T08:27:18+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"11 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/\",\"url\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/\",\"name\":\"Microport CRM CRT Left Ventricular Pacing | Cardiocases\",\"isPartOf\":{\"@id\":\"https:\/\/cardiocases.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p27-1024x691.jpg\",\"datePublished\":\"2025-07-31T14:24:09+00:00\",\"dateModified\":\"2026-02-01T08:27:18+00:00\",\"description\":\"Microport CRM CRT left ventricular pacing \u2014 LV programming, output optimization & real ECG tracings.\",\"breadcrumb\":{\"@id\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/#primaryimage\",\"url\":\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p27-1024x691.jpg\",\"contentUrl\":\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p27-1024x691.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/cardiocases.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pacing &amp; Defibrillation\",\"item\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Devices per company\",\"item\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Microport CRM\",\"item\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Left ventricular pacing Microport\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/cardiocases.com\/#website\",\"url\":\"https:\/\/cardiocases.com\/\",\"name\":\"Cardiocases\",\"description\":\"Real cardiac device traces, pacemaker &amp; ICD learning \u2014 built by electrophysiologists\",\"publisher\":{\"@id\":\"https:\/\/cardiocases.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/cardiocases.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/cardiocases.com\/#organization\",\"name\":\"Cardiocases\",\"url\":\"https:\/\/cardiocases.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png\",\"contentUrl\":\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png\",\"width\":1755,\"height\":499,\"caption\":\"Cardiocases\"},\"image\":{\"@id\":\"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/cardiocases\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Microport CRM CRT Left Ventricular Pacing | Cardiocases","description":"Microport CRM CRT left ventricular pacing \u2014 LV programming, output optimization & real ECG tracings.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/","og_locale":"fr_FR","og_type":"article","og_title":"Microport CRM CRT Left Ventricular Pacing | Cardiocases","og_description":"Microport CRM CRT left ventricular pacing \u2014 LV programming, output optimization & real ECG tracings.","og_url":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/","og_site_name":"Cardiocases","article_modified_time":"2026-02-01T08:27:18+00:00","twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"11 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/","url":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/","name":"Microport CRM CRT Left Ventricular Pacing | Cardiocases","isPartOf":{"@id":"https:\/\/cardiocases.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/#primaryimage"},"image":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/#primaryimage"},"thumbnailUrl":"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p27-1024x691.jpg","datePublished":"2025-07-31T14:24:09+00:00","dateModified":"2026-02-01T08:27:18+00:00","description":"Microport CRM CRT left ventricular pacing \u2014 LV programming, output optimization & real ECG tracings.","breadcrumb":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/#primaryimage","url":"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p27-1024x691.jpg","contentUrl":"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2022\/10\/p27-1024x691.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/left-ventricular-pacing-microport\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cardiocases.com\/"},{"@type":"ListItem","position":2,"name":"Pacing &amp; Defibrillation","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/"},{"@type":"ListItem","position":3,"name":"Devices per company","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/"},{"@type":"ListItem","position":4,"name":"Microport CRM","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/"},{"@type":"ListItem","position":5,"name":"Left ventricular pacing Microport"}]},{"@type":"WebSite","@id":"https:\/\/cardiocases.com\/#website","url":"https:\/\/cardiocases.com\/","name":"Cardiocases","description":"Real cardiac device traces, pacemaker &amp; ICD learning \u2014 built by electrophysiologists","publisher":{"@id":"https:\/\/cardiocases.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cardiocases.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/cardiocases.com\/#organization","name":"Cardiocases","url":"https:\/\/cardiocases.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/","url":"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png","contentUrl":"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png","width":1755,"height":499,"caption":"Cardiocases"},"image":{"@id":"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/cardiocases\/"]}]}},"_links":{"self":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/814","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/comments?post=814"}],"version-history":[{"count":9,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/814\/revisions"}],"predecessor-version":[{"id":9095,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/814\/revisions\/9095"}],"up":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/53"}],"wp:attachment":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/media?parent=814"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}