{"id":3593,"date":"2025-10-08T18:41:56","date_gmt":"2025-10-08T18:41:56","guid":{"rendered":"https:\/\/cardiocases.com\/?page_id=3593"},"modified":"2026-07-16T16:05:28","modified_gmt":"2026-07-16T16:05:28","slug":"pacing-detection-microport","status":"publish","type":"page","link":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/","title":{"rendered":"Pacing \/ Detection Microport"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"3593\" class=\"elementor elementor-3593\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-87fccdb e-con-full e-flex e-con e-parent\" data-id=\"87fccdb\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-83d6b7e elementor-widget elementor-widget-heading\" data-id=\"83d6b7e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span style=\"font-size: 2rem\">Microport - <\/span>Pacing \/ Sensing<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1271082 elementor-toc--minimized-on-tablet elementor-widget elementor-widget-table-of-contents\" data-id=\"1271082\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;headings_by_tags&quot;:[&quot;h3&quot;,&quot;h4&quot;,&quot;h5&quot;],&quot;exclude_headings_by_selector&quot;:[],&quot;no_headings_message&quot;:&quot;No headings were found on this page.&quot;,&quot;marker_view&quot;:&quot;bullets&quot;,&quot;icon&quot;:{&quot;value&quot;:&quot;fas fa-circle&quot;,&quot;library&quot;:&quot;fa-solid&quot;,&quot;rendered_tag&quot;:&quot;&lt;svg class=\\&quot;e-font-icon-svg e-fas-circle\\&quot; viewBox=\\&quot;0 0 512 512\\&quot; xmlns=\\&quot;http:\\\/\\\/www.w3.org\\\/2000\\\/svg\\&quot;&gt;&lt;path d=\\&quot;M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\\&quot;&gt;&lt;\\\/path&gt;&lt;\\\/svg&gt;&quot;},&quot;minimize_box&quot;:&quot;yes&quot;,&quot;minimized_on&quot;:&quot;tablet&quot;,&quot;hierarchical_view&quot;:&quot;yes&quot;,&quot;min_height&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"table-of-contents.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__header\">\n\t\t\t\t\t\t<h4 class=\"elementor-toc__header-title\">\n\t\t\t\tContent\t\t\t<\/h4>\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--expand\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__1271082\" aria-expanded=\"true\" aria-label=\"Ouvrir la table des mati\u00e8res\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/div>\n\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--collapse\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__1271082\" aria-expanded=\"true\" aria-label=\"Fermer la table des mati\u00e8res\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<div id=\"elementor-toc__1271082\" class=\"elementor-toc__body\">\n\t\t\t<div class=\"elementor-toc__spinner-container\">\n\t\t\t\t<svg class=\"elementor-toc__spinner eicon-animation-spin e-font-icon-svg e-eicon-loading\" aria-hidden=\"true\" viewBox=\"0 0 1000 1000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M500 975V858C696 858 858 696 858 500S696 142 500 142 142 304 142 500H25C25 237 238 25 500 25S975 237 975 500 763 975 500 975Z\"><\/path><\/svg>\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ddd6644 elementor-widget elementor-widget-heading\" data-id=\"ddd6644\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Atrial pacing<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f069f3c elementor-widget elementor-widget-text-editor\" data-id=\"f069f3c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>No automatic atrial threshold measurement performed by Microport CRM-Sorin pacemakers.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f600310 elementor-widget elementor-widget-heading\" data-id=\"f600310\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ventricular pacing<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cdcaf1f elementor-widget elementor-widget-text-editor\" data-id=\"cdcaf1f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><\/p><p><\/p><p>6) 2 m\u00e9thodes de mesure de seuil atrial peuvent \u00eatre utilis\u00e9es par le dispositif : une m\u00e9thode bas\u00e9e sur la d\u00e9tection d\u2019une activit\u00e9 atriale spontan\u00e9e t\u00e9moin de la perte de <br \/>capture atriale et une m\u00e9thode bas\u00e9e sur l\u2019absence de d\u00e9tection ventriculaire suivant une stimulation atriale (patients avec conduction auriculoventriculaire pr\u00e9serv\u00e9e)<br \/>7) Le dispositif mesure p\u00e9riodiquement le seuil de stimulation atriale tous les jours \u00e0 1 heure du matin<br \/>8) L\u2019amplitude de stimulation atriale est adapt\u00e9e automatiquement en ajoutant 1 V \u00e0 la valeur du seuil mesur\u00e9 dans les limites d\u2019une valeur minimale programmable<br \/>9) La dur\u00e9e d\u2019impulsion est programmable <br \/>10) Il n\u2019y a pas de v\u00e9rification cycle-\u00e0-cycle de l\u2019efficacit\u00e9 de la capture atriale ; l\u2019adaptation <br \/>de l\u2019amplitude de stimulation atriale est bas\u00e9e sur le concept de l\u2019Autoseuil ; la m\u00eame <br \/>amplitude est d\u00e9livr\u00e9e (seuil mesur\u00e9 + marge de s\u00e9curit\u00e9) jusqu\u2019\u00e0 la prochaine mesure <br \/>de seuil automatique<\/p><h5><strong>Autoseuil ventriculaire<\/strong><\/h5><p><strong>G\u00e9n\u00e9ralit\u00e9s<\/strong><br \/>La fonction d\u2019Autoseuil ventriculaire est disponible quel que soit le mode de stimulation <br \/>permettant une stimulation ventriculaire \u00e0 l\u2019exception du mode SafeR.<\/p><ul><li>\u00a0Autoseuil sur auto : mesures r\u00e9guli\u00e8res du seuil de stimulation ventriculaire + adaptation de la programmation<\/li><li>\u00a0Mesure du seuil r\u00e9alis\u00e9e syst\u00e9matiquement toutes les 6 heures (bas\u00e9e sur l\u2019analyse de la r\u00e9ponse \u00e9voqu\u00e9e)<\/li><li>4 mesures de seuil par jour avec adaptation pour les 6 heures suivantes (pas de v\u00e9rification cycle \u00e0 cycle)<\/li><li>\u00a0Adaptation automatique de l\u2019amplitude au double de la valeur de seuil (marge de s\u00e9curit\u00e9 de 100%) dans la limite d\u2019une valeur minimale programmable (1.5, 2, 2.5, 3, 3.5 ou 4 V)<\/li><li>\u00a0Autoseuil sur suivi : mesures r\u00e9guli\u00e8res du seuil de stimulation ventriculaire mais sans adaptation de la programmation<\/li><li>\u00a0Autoseuil sur non : pas de mesure de seuil et valeur fixes<\/li><\/ul><p><strong>L\u2019autoseuil ventriculaire en pratique<\/strong> <br \/>Le test de capture est bas\u00e9 sur la diff\u00e9rentiation entre le potentiel \u00e9voqu\u00e9 (EPR) et la polarisation r\u00e9siduelle de la sonde (Polar). Apr\u00e8s un stimulus efficace, durant une p\u00e9riode de 65 ms, les 2 potentiels sont pr\u00e9sents (EPR + Polar) alors qu\u2019apr\u00e8s un stimulus inefficace, seule la polarisation r\u00e9siduelle de la sonde est pr\u00e9sente (Polar).<img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-11479 size-full\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation.png\" alt=\"\" width=\"502\" height=\"355\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation.png 502w, https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-300x212.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-18x12.png 18w\" sizes=\"(max-width: 502px) 100vw, 502px\" \/><\/p><p>La proc\u00e9dure de mesure du seuil se d\u00e9compose en une phase d\u2019attente, une phase de <br \/>calibration et une phase de mesure du seuil<\/p><p><img decoding=\"async\" class=\"aligncenter wp-image-11480 size-full\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-2.png\" alt=\"\" width=\"589\" height=\"336\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-2.png 589w, https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-2-300x171.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-2-18x10.png 18w\" sizes=\"(max-width: 589px) 100vw, 589px\" \/><\/p><p><strong>Phase d\u2019attente<\/strong><\/p><ul><li>L\u2019objectif de cette phase est de stabiliser le rythme<\/li><li>8 stimulations \u00e0 5 V sont d\u00e9livr\u00e9es<\/li><\/ul><p><strong>Phase de calibration<\/strong> <br \/>L\u2019objectif de la phase de calibration est double :<\/p><ul><li>Rep\u00e9rer un seuil de stimulation initialement \u00e9lev\u00e9 (sup\u00e9rieur \u00e0 2V)<\/li><li>Mesurer le potentiel de r\u00e9ponse \u00e9voqu\u00e9e<\/li><\/ul><p>Dans le but d\u2019augmenter la probabilit\u00e9 de capturer le ventricule, le d\u00e9lai AV courant <br \/>est raccourci de 65 ms (stimulateur double chambre) ou l\u2019intervalle d\u2019\u00e9chappement est raccourci de 65 ms (stimulateur simple chambre).<\/p><ul><li>Trois stimulations \u00e0 4 V (\u00e0 la largeur d\u2019impulsion programm\u00e9e) sont d\u00e9livr\u00e9es et seules les 2 derni\u00e8res sont suivies de la mesure de la r\u00e9ponse \u00e9voqu\u00e9e et de la polarisation<\/li><li>Trois stimulations \u00e0 2 V (\u00e0 la largeur d\u2019impulsion programm\u00e9e) sont d\u00e9livr\u00e9es et seules les 2 derni\u00e8res sont suivies d\u2019une mesure de la r\u00e9ponse \u00e9voqu\u00e9e et de la polarisation<\/li><li>Ces 3 stimulations \u00e0 2 V sont suivies chacune apr\u00e8s la p\u00e9riode de mesure (65 ms), d\u2019une stimulation de s\u00e9curit\u00e9 \u00e0 2,5 V avec une largeur d\u2019impulsion de 1 ms ; l\u2019objectif de ces stimulations de s\u00e9curit\u00e9 est d\u2019assurer une capture ventriculaire en cas de seuil de stimulation sup\u00e9rieur \u00e0 2 V<\/li><li>\u00a0Si ces deux s\u00e9ries donnent des mesures acceptables et comparables, le stimulateur applique l\u2019\u00e9tape suivante<\/li><li>Deux \u201cstimulations \u00e0 0 V\u201d sont suivies par une p\u00e9riode de mesure de la r\u00e9ponse \u00e9voqu\u00e9e et de la polarisation ; elles permettent de faire le diagnostic de fusion qui peut alt\u00e9rer la mesure du seuil ; en effet si apr\u00e8s une\u201cstimulation \u00e0 0 V\u201d, des potentiels \u00e9voqu\u00e9s spontan\u00e9s sont mesur\u00e9s, ils sont r\u00e9v\u00e9lateurs de la pr\u00e9sence d\u2019une fusion possible ou de d\u00e9polarisations ectopiques lors des mesures pr\u00e9c\u00e9dentes (\u00e0 2 et 4 V) ; la phase de calibration est alors refaite avec un d\u00e9lai AV court (65 ms) pour \u00e9viter la fusion ; si malgr\u00e9 ce r\u00e9glage une fusion est encore d\u00e9tect\u00e9e, le test est arr\u00eat\u00e9 et la tension ventriculaire est forc\u00e9e \u00e0 5 V pour les six prochaines heures<img decoding=\"async\" class=\"aligncenter wp-image-11481 size-full\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-3.png\" alt=\"\" width=\"718\" height=\"229\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-3.png 718w, https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-3-300x96.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-3-18x6.png 18w\" sizes=\"(max-width: 718px) 100vw, 718px\" \/><\/li><\/ul><p><strong>Phase de mesure du seuil de stimulation ventriculaire<\/strong><\/p><ul><li>\u00a0\u00c0 la suite de la phase de calibration, le test de seuil de stimulation commence \u00e0 partir de 1,95 V avec un d\u00e9cr\u00e9ment de 0,15 V jusqu\u2019\u00e0 de perte de capture ou jusqu\u2019\u00e0 la valeur de 0,15 V au minimum<\/li><li>\u00a0Chaque stimulation est suivie d\u2019une fen\u00eatre de mesure (65 ms)<\/li><li>\u00a0En cas de perte de capture, une stimulation de s\u00e9curit\u00e9 \u00e0 2,5 V avec une largeur d\u2019impulsion de 1 ms est d\u00e9livr\u00e9e<\/li><\/ul><p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-11486 size-full\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-4.png\" alt=\"\" width=\"645\" height=\"252\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-4.png 645w, https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-4-300x117.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation-4-18x7.png 18w\" sizes=\"(max-width: 645px) 100vw, 645px\" \/><\/p><p>Dans cet exemple le seuil V est de 1,5 V. L\u2019amplitude ventriculaire est programm\u00e9e \u00e0 3 V pour les 6 prochaines heures. La valeur de 1,5 V est affich\u00e9e sur la courbe d\u2019Autoseuil ainsi que la tension de stimulation appliqu\u00e9e durant les 6 heures suivantes.<\/p><p><strong>Programmation<\/strong><\/p><ul><li>L\u2019Autoseuil Ventriculaire n\u2019est pas disponible avec le mode SafeR<\/li><li>La mesure du seuil ne peut s\u2019effectuer que si la fr\u00e9quence cardiaque est inf\u00e9rieure \u00e0 95 bpm<\/li><li>\u00a0L\u2019amplitude de stimulation ventriculaire est non programmable lorsque la fonction Autoseuil V est programm\u00e9e sur \u201cAuto\u201d<\/li><li>Il n\u2019est pas possible de programmer une valeur de dur\u00e9e d\u2019impulsion ventriculaire sup\u00e9rieure \u00e0 0,5ms lorsque la fonction Autoseuil V est programm\u00e9e sur \u201cSuivi\u201d ou \u201cAuto\u201d <img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-11487 size-full\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/Microport-prog.png\" alt=\"\" width=\"742\" height=\"559\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/Microport-prog.png 742w, https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/Microport-prog-300x226.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/Microport-prog-16x12.png 16w\" sizes=\"(max-width: 742px) 100vw, 742px\" \/><\/li><\/ul><h5><strong>Mesure automatique du seuil atrial <\/strong><\/h5><p>G\u00e9n\u00e9ralit\u00e9s <br \/>L\u2019Autoseuil atrial est disponible sur les derni\u00e8res plateformes. Le fonctionnement est bas\u00e9 <br \/>sur 3 grands principes :<\/p><ul><li>Le seuil de stimulation atriale est r\u00e9alis\u00e9 une fois par jour, la nuit (1h du matin)<\/li><li>Il existe 2 m\u00e9thodes pour mesurer le seuil de stimulation (PR ou AR) choisies automatiquement <br \/>par le dispositif en fonction de l\u2019existence d\u2019un rythme sinusal stable et sup\u00e9rieur \u00e0 50 bpm (seuil r\u00e9alis\u00e9 avec incr\u00e9ment de l\u2019amplitude de stimulation) ou d\u2019une conduction atrio-ventriculaire en 1\/1 avec intervalles AR stables (seuil r\u00e9alis\u00e9 avec d\u00e9cr\u00e9ment de l\u2019amplitude de stimulation)<\/li><li>\u00a0L\u2019absence de capture atriale est \u00e9valu\u00e9e de fa\u00e7on indirecte et est sugg\u00e9r\u00e9e devant la reprise d\u2019une activit\u00e9 atriale spontan\u00e9e<\/li><li>L\u2019amplitude de stimulation atriale est automatiquement adapt\u00e9e pour les 24 heures suivantes \u00e0 une valeur sup\u00e9rieure de 1 V par rapport au seuil mesur\u00e9 ou \u00e0 la valeur minimale de stimulation atriale programm\u00e9e (valeur la plus \u00e9lev\u00e9e entre les 2)<\/li><\/ul><p><\/p><h2><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-efb4f9b elementor-widget elementor-widget-heading\" data-id=\"efb4f9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Sensing<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3359536 elementor-widget elementor-widget-text-editor\" data-id=\"3359536\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><\/p><p><\/p><p><strong>Autosensing<\/strong><br \/>Il est possible de programmer la fonction Autosensing Atrial et Ventriculaire avec adaptation automatique des sensibilit\u00e9s A et V aux variations d\u2019amplitude des \u00e9v\u00e8nements d\u00e9tect\u00e9s. L\u2019amplitude des \u00e9v\u00e8nements atriaux et ventriculaires est monitor\u00e9e en <br \/>permanence avec adaptation automatique cycle \u00e0 cycle des sensibilit\u00e9s. L\u2019amplitude des <br \/>signaux est moyenn\u00e9e sur 8 cycles cons\u00e9cutifs et la sensibilit\u00e9 est programm\u00e9e \u00e0 environ un tiers (37,5%) de cette valeur moyenne.<\/p><p><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0ed6d75 elementor-widget elementor-widget-image\" data-id=\"0ed6d75\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection13.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection13\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAyNSwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTMucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"289\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection13.png\" class=\"attachment-large size-large wp-image-5025\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection13.png 700w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection13-300x124.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection13-18x7.png 18w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-af92bef elementor-widget elementor-widget-text-editor\" data-id=\"af92bef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Following an atrial extrasystole, atrial arrhythmia, or atrial stimulation, atrial sensitivity is forced to 0.4 mV. The amplitude of the PAC is not included in the average. It is replaced by the value 0.4 mV for the calculation of the average amplitude. Autosensing A applies a sensitivity ranging from 0.4 mV to 3 mV.<\/p><p>Similarly, following ventricular pacing, ventricular sensitivity is forced to 1.5 mV in unipolar mode and 2 mV in bipolar mode. Autosensing V applies a sensitivity ranging from 1.5 mV (in unipolar mode) or 2 mV (in bipolar mode) to 6 mV.<\/p><p><strong>Programming<\/strong><\/p><p>Autosensing can be programmed to:<\/p><ol><li>MONITORING, which measures the amplitudes of P waves (sinus and pathological) and R waves (normal and PVC) without adjusting the sensitivity settings, which remain fixed<\/li><li>AUTO, which measures the amplitudes of P waves and R waves with automatic adjustment of sensitivities as described above<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-025af5b elementor-widget elementor-widget-image\" data-id=\"025af5b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection14.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection14\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAyNiwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTQucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"691\" height=\"332\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection14.png\" class=\"attachment-large size-large wp-image-5026\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection14.png 691w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection14-300x144.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection14-18x9.png 18w\" sizes=\"(max-width: 691px) 100vw, 691px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b50187 elementor-widget elementor-widget-text-editor\" data-id=\"1b50187\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>There are a number of restrictions: atrial autosensing can only be programmed to auto if atrial sensitivity is bipolar (if unipolar, only follow mode) and the AV rest delay is greater than 65 ms.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3a4aad elementor-widget elementor-widget-image\" data-id=\"c3a4aad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection15.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection15\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAyNywidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTUucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"469\" height=\"296\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection15.png\" class=\"attachment-large size-large wp-image-5027\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection15.png 469w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection15-300x189.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection15-18x12.png 18w\" sizes=\"(max-width: 469px) 100vw, 469px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03e00ba elementor-widget elementor-widget-text-editor\" data-id=\"03e00ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Stored data<\/strong><\/p><p>The amplitude measurements of detected events are presented in the form of distribution histograms. Detection quality can also be assessed using trend curves for the last 24 hours, where the accuracy (average value) is approximately 8 minutes per point, and trend curves for the last 6 months, where each point represents the average detection value for one day.<\/p><p>In the PM tab of the AIDA Diagnosis screen, clicking on the Autosensing magnifying glass displays the distribution of P waves; clicking on the P\/R Waves button displays the distribution of R waves; clicking on the Track over the last 24 hours button displays the trend curves for P and R waves over the last 24 hours.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8022d4 elementor-widget elementor-widget-image\" data-id=\"b8022d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection16.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection16\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAyOCwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTYucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"685\" height=\"540\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection16.png\" class=\"attachment-large size-large wp-image-5028\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection16.png 685w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection16-300x236.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection16-15x12.png 15w\" sizes=\"(max-width: 685px) 100vw, 685px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54fe02d elementor-widget elementor-widget-text-editor\" data-id=\"54fe02d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>\u201cSinusoidal\u201d P waves represent P wave detections outside the WARAD. \u201cRetrograde\u201d P waves represent P wave detections occurring during the retrograde phase (DDI). P wave detections occurring during the suspected phase are not taken into account.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-654390f elementor-widget elementor-widget-image\" data-id=\"654390f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection17.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection17\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAyOSwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTcucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"690\" height=\"545\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection17.png\" class=\"attachment-large size-large wp-image-5029\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection17.png 690w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection17-300x237.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection17-15x12.png 15w\" sizes=\"(max-width: 690px) 100vw, 690px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-78878a3 elementor-widget elementor-widget-text-editor\" data-id=\"78878a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>PVCs represent R-wave detections whose coupling is 25% shorter than the average of the preceding 4 \u201cnormal\u201d ventricular cycles.<\/p><p>Note that in Symphony, the measurement period represents the last 6 months. In Reply, Reply 200, and Kora 100, the measurement period is equivalent to the last 2 months.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c09a95f elementor-widget elementor-widget-image\" data-id=\"c09a95f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection18.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection18\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAzMCwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTgucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"683\" height=\"545\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection18.png\" class=\"attachment-large size-large wp-image-5030\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection18.png 683w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection18-300x239.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection18-15x12.png 15w\" sizes=\"(max-width: 683px) 100vw, 683px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5ca347c elementor-widget elementor-widget-text-editor\" data-id=\"5ca347c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>In the PM tab of the AIDA Diagnostics screen, clicking on the Probe Measurements magnifying glass displays the atrial detection trend curves; clicking on the V Probe button displays the ventricular detection trend curves.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-072df45 elementor-widget elementor-widget-image\" data-id=\"072df45\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection19.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection19\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAzMSwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTkucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"691\" height=\"548\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection19.png\" class=\"attachment-large size-large wp-image-5031\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection19.png 691w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection19-300x238.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection19-15x12.png 15w\" sizes=\"(max-width: 691px) 100vw, 691px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-711096e elementor-widget elementor-widget-image\" data-id=\"711096e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection20.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection20\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAzMiwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMjAucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"688\" height=\"552\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection20.png\" class=\"attachment-large size-large wp-image-5032\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection20.png 688w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection20-300x241.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection20-15x12.png 15w\" sizes=\"(max-width: 688px) 100vw, 688px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Microport &#8211; Pacing \/ Sensing Content Atrial pacing No automatic atrial threshold measurement performed by Microport CRM-Sorin pacemakers. Ventricular pacing Sensing Following an atrial extrasystole, atrial arrhythmia, or atrial stimulation, atrial sensitivity is forced to 0.4 mV. The amplitude of the PAC is not included in the average. It is replaced by the value 0.4 [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":53,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-3593","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Microport CRM Pacemaker Pacing &amp; Detection | Cardiocases<\/title>\n<meta name=\"description\" content=\"Microport CRM pacemaker pacing &amp; detection \u2014 output, sensitivity, sensing &amp; ECG tracings. For electrophysiologists.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Microport CRM Pacemaker Pacing &amp; Detection | Cardiocases\" \/>\n<meta property=\"og:description\" content=\"Microport CRM pacemaker pacing &amp; detection \u2014 output, sensitivity, sensing &amp; ECG tracings. For electrophysiologists.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/\" \/>\n<meta property=\"og:site_name\" content=\"Cardiocases\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-16T16:05:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/\",\"name\":\"Microport CRM Pacemaker Pacing & Detection | Cardiocases\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/microport-stimulation.png\",\"datePublished\":\"2025-10-08T18:41:56+00:00\",\"dateModified\":\"2026-07-16T16:05:28+00:00\",\"description\":\"Microport CRM pacemaker pacing & detection \u2014 output, sensitivity, sensing & ECG tracings. For electrophysiologists.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/#primaryimage\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/microport-stimulation.png\",\"contentUrl\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/microport-stimulation.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/cardiocases.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pacing &amp; Defibrillation\",\"item\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Devices per company\",\"item\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Microport CRM\",\"item\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Pacing \\\/ Detection Microport\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#website\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/\",\"name\":\"Cardiocases\",\"description\":\"Real cardiac device traces, pacemaker &amp; ICD learning \u2014 built by electrophysiologists\",\"publisher\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/cardiocases.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#organization\",\"name\":\"Cardiocases\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cardiocases_logo.png\",\"contentUrl\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cardiocases_logo.png\",\"width\":1755,\"height\":499,\"caption\":\"Cardiocases\"},\"image\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/cardiocases\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Microport CRM Pacemaker Pacing & Detection | Cardiocases","description":"Microport CRM pacemaker pacing & detection \u2014 output, sensitivity, sensing & ECG tracings. For electrophysiologists.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/","og_locale":"fr_FR","og_type":"article","og_title":"Microport CRM Pacemaker Pacing & Detection | Cardiocases","og_description":"Microport CRM pacemaker pacing & detection \u2014 output, sensitivity, sensing & ECG tracings. For electrophysiologists.","og_url":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/","og_site_name":"Cardiocases","article_modified_time":"2026-07-16T16:05:28+00:00","og_image":[{"url":"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/","url":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/","name":"Microport CRM Pacemaker Pacing & Detection | Cardiocases","isPartOf":{"@id":"https:\/\/cardiocases.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/#primaryimage"},"image":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/#primaryimage"},"thumbnailUrl":"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation.png","datePublished":"2025-10-08T18:41:56+00:00","dateModified":"2026-07-16T16:05:28+00:00","description":"Microport CRM pacemaker pacing & detection \u2014 output, sensitivity, sensing & ECG tracings. For electrophysiologists.","breadcrumb":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/#primaryimage","url":"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation.png","contentUrl":"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/07\/microport-stimulation.png"},{"@type":"BreadcrumbList","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cardiocases.com\/"},{"@type":"ListItem","position":2,"name":"Pacing &amp; Defibrillation","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/"},{"@type":"ListItem","position":3,"name":"Devices per company","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/"},{"@type":"ListItem","position":4,"name":"Microport CRM","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/"},{"@type":"ListItem","position":5,"name":"Pacing \/ Detection Microport"}]},{"@type":"WebSite","@id":"https:\/\/cardiocases.com\/#website","url":"https:\/\/cardiocases.com\/","name":"Cardiocases","description":"Real cardiac device traces, pacemaker &amp; ICD learning \u2014 built by electrophysiologists","publisher":{"@id":"https:\/\/cardiocases.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cardiocases.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/cardiocases.com\/#organization","name":"Cardiocases","url":"https:\/\/cardiocases.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/","url":"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png","contentUrl":"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png","width":1755,"height":499,"caption":"Cardiocases"},"image":{"@id":"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/cardiocases\/"]}]}},"_links":{"self":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/3593","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/comments?post=3593"}],"version-history":[{"count":21,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/3593\/revisions"}],"predecessor-version":[{"id":11497,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/3593\/revisions\/11497"}],"up":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/53"}],"wp:attachment":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/media?parent=3593"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}