{"id":3593,"date":"2025-10-08T18:41:56","date_gmt":"2025-10-08T18:41:56","guid":{"rendered":"https:\/\/cardiocases.com\/?page_id=3593"},"modified":"2026-01-24T16:46:17","modified_gmt":"2026-01-24T16:46:17","slug":"pacing-detection-microport","status":"publish","type":"page","link":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/","title":{"rendered":"Pacing \/ Detection Microport"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"3593\" class=\"elementor elementor-3593\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-87fccdb e-con-full e-flex e-con e-parent\" data-id=\"87fccdb\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-83d6b7e elementor-widget elementor-widget-heading\" data-id=\"83d6b7e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span style=\"font-size: 2rem\">Microport - <\/span>Pacing \/ Sensing<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1271082 elementor-toc--minimized-on-tablet elementor-widget elementor-widget-table-of-contents\" data-id=\"1271082\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;headings_by_tags&quot;:[&quot;h3&quot;,&quot;h4&quot;,&quot;h5&quot;],&quot;exclude_headings_by_selector&quot;:[],&quot;no_headings_message&quot;:&quot;No headings were found on this page.&quot;,&quot;marker_view&quot;:&quot;bullets&quot;,&quot;icon&quot;:{&quot;value&quot;:&quot;fas fa-circle&quot;,&quot;library&quot;:&quot;fa-solid&quot;,&quot;rendered_tag&quot;:&quot;&lt;svg class=\\&quot;e-font-icon-svg e-fas-circle\\&quot; viewBox=\\&quot;0 0 512 512\\&quot; xmlns=\\&quot;http:\\\/\\\/www.w3.org\\\/2000\\\/svg\\&quot;&gt;&lt;path d=\\&quot;M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\\&quot;&gt;&lt;\\\/path&gt;&lt;\\\/svg&gt;&quot;},&quot;minimize_box&quot;:&quot;yes&quot;,&quot;minimized_on&quot;:&quot;tablet&quot;,&quot;hierarchical_view&quot;:&quot;yes&quot;,&quot;min_height&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"table-of-contents.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__header\">\n\t\t\t\t\t\t<h4 class=\"elementor-toc__header-title\">\n\t\t\t\tContent\t\t\t<\/h4>\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--expand\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__1271082\" aria-expanded=\"true\" aria-label=\"Ouvrir la table des mati\u00e8res\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/div>\n\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--collapse\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__1271082\" aria-expanded=\"true\" aria-label=\"Fermer la table des mati\u00e8res\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<div id=\"elementor-toc__1271082\" class=\"elementor-toc__body\">\n\t\t\t<div class=\"elementor-toc__spinner-container\">\n\t\t\t\t<svg class=\"elementor-toc__spinner eicon-animation-spin e-font-icon-svg e-eicon-loading\" aria-hidden=\"true\" viewBox=\"0 0 1000 1000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M500 975V858C696 858 858 696 858 500S696 142 500 142 142 304 142 500H25C25 237 238 25 500 25S975 237 975 500 763 975 500 975Z\"><\/path><\/svg>\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ddd6644 elementor-widget elementor-widget-heading\" data-id=\"ddd6644\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Atrial pacing<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f069f3c elementor-widget elementor-widget-text-editor\" data-id=\"f069f3c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>No automatic atrial threshold measurement performed by Microport CRM-Sorin pacemakers.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f600310 elementor-widget elementor-widget-heading\" data-id=\"f600310\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Ventricular pacing<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cdcaf1f elementor-widget elementor-widget-text-editor\" data-id=\"cdcaf1f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>The Ventricular Autothreshold function is available in all pacing modes, which provide ventricular pacing except in SafeR and Dplus pacing mode.<\/p><ul><li>periodical measurement (6 hours, 4 times a day) of the ventricular pacing threshold<\/li><li>automatic adjustment of the ventricular pacing amplitude to provide a 100% safety margin for the next 6 hours<\/li><li>no beat to beat verification of capture efficiency<\/li><li>a minimum ventricular amplitude is programmable<\/li><\/ul><p>\u00a0<\/p><h2><strong>Periodical measurement of the ventricular threshold<\/strong><\/h2><p>The automatic threshold test sequence is automatically launched:<\/p><ul><li>every 6 hours<\/li><li>after a ventricular manual threshold test<\/li><li>after reprogramming of the auto threshold function from OFF to \u201cMONITOR\u201d or AUTO<\/li><li>after a magnet test<\/li><li>after programming of the V pulse width and V pacing polarity<\/li><\/ul><p><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2020\/10\/Ventricular-Autothreshold-algorithm-1.jpg\" target=\"_blank\" rel=\"noopener\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-17708 size-full\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2020\/10\/Ventricular-Autothreshold-algorithm-1.jpg\" alt=\"\" width=\"770\" height=\"531\" \/><\/a><\/p><p>\u00a0<\/p><ul><li>Threshold test can start as soon as calibration and fusion tests are successful.<\/li><li>Output set at twice this value but not less than the programmed minimum amplitude.<\/li><li>If threshold is not found, value of the previous test is kept and the test is relaunched in 15 minutes. There are up to 5 retries (except for SafeR and Dplus)*.<\/li><\/ul><p>\u00a0<\/p><p><em>Waiting phase<\/em><\/p><p>8 cardiac cycles are delivered at the current pacing rate.<\/p><ul><li>ventricular amplitude programmed at 5 V (programmed pulse width)<\/li><li>the calibration phase can start if the device could pace with an AV delay &gt; 125 ms and a pacing rate &lt; 95 min-1, during 8 cardiac cycles<\/li><\/ul><p>\u00a0<\/p><p><em>Calibration phase<\/em><\/p><p>The calibration phase is required to demonstrate an appropriate differentiation of the evoked potential response (EPR) and of the post-pacing polarization of the electrode. The signal is analyzed in a window of 65 ms following ventricular pacing.<\/p><ul><li>capture: post-pacing polarization+ evoked response<\/li><li>non capture: post-pacing polarization<\/li><\/ul><p>To reduce the risk of fusion beats during the calibration phase and the threshold test:<\/p><ul><li>the AV delay is shortened by 65 ms in DDD or VDD<\/li><li>the escape interval is shortened by 65 ms in VVI, DDI and fallback mode switch<\/li><\/ul><p>During the calibration phase, different pacing amplitudes are delivered:<\/p><ul><li>3 ventricular stimuli at 4 V (programmed pulse width): first stimulus to avoid Wedensky effect; calibration on the 2 following spikes with evaluation of the signal in a 65 ms window; average of the 2 measurements<\/li><li>3 ventricular stimuli at 2 V + safety pulse at 2.5 V\/1 ms: first stimulus to avoid Wedensky effect; calibration on the 2 following spikes with evaluation of the signal in a 65 ms window; average of the 2 measurements<\/li><li>comparison of the average measurements at 4V and 2V to demonstrate similar evoked response<\/li><li>During 2 cycles, the device assesses the fusion possibility. At the end of the AVD, it evaluates the signal in a 65 ms window and measures the ventricular amplitude. Then a back-up spike of 2.5 V\/1 ms is applied at the end of the 65 ms window. During the 65 ms window<ul><li>If the device identifies spontaneous ventricular depolarisation similar to ventricular \u201ccapture\u201d, fusion beats could be suspected for 4 V and 2 V capture verification (or it could be also an ectopic beat). It means that fusion could also occur during threshold test. Then the device restart the second calibration with the forced AV delay to 65 ms.<\/li><li>If no depolarisation, then no fusion is suspected, the next step starts (Threshold test).<\/li><\/ul><\/li><\/ul><p>\u00a0<\/p><p><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2020\/10\/Ventricular-Autothreshold-algorithm-2.jpg\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"aligncenter wp-image-17709 size-full\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2020\/10\/Ventricular-Autothreshold-algorithm-2.jpg\" alt=\"\" width=\"1037\" height=\"455\" \/><\/a><\/p><p>\u00a0<\/p><p>The calibration phase fails when:<\/p><ul><li>diagnosis of fusion beats (even after the second calibration)<\/li><li>excessive polarization (poor ratio evoked response\/polarization)<\/li><li>pacing threshold higher than 2 V<\/li><\/ul><p>If the calibration phase fails, the ventricular amplitude is set to 5 V and test restarts 6 hours later.<\/p><p>\u00a0<\/p><p><em>Threshold test<\/em><\/p><p>The threshold test is performed at the programmed pulse width and pacing polarity.<\/p><ul><li>threshold test starts at 1.85 V<\/li><li>steps of 0.15 V<\/li><li>threshold test stops after a loss of capture or at the amplitude of 0.2 V<\/li><li>after a loss of capture, a safety pulse is delivered after 65 ms (amplitude 2.5 V, pulse width 1 ms)<\/li><\/ul><p>\u00a0<\/p><p><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2020\/10\/Right-Ventricular-Autothreshold-RVAT-EGM-threshold.jpg\"><img decoding=\"async\" class=\"aligncenter size-full wp-image-14480\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2020\/10\/Right-Ventricular-Autothreshold-RVAT-EGM-threshold.jpg\" alt=\"\" width=\"1652\" height=\"795\" \/><\/a><\/p><p>\u00a0<\/p><p>\u00a0<\/p><h2><strong>Adjustment of the amplitude<\/strong><\/h2><ul><li>the minimum ventricular amplitude is 1.5 V (programmable)<\/li><li>automatic adjustment of the ventricular pacing amplitude to provide a 100% safety margin for the next 6 hours (measured threshold x 2)<\/li><li>threshold test starts at 1.85 V<\/li><li>steps of 0.15 V<\/li><li>stops after a loss of capture, a safety pulse is delivered after 65 ms (amplitude 2.5 V, pulse width 1 ms)<\/li><\/ul><p>\u00a0<\/p><h2><strong>Programmable parameters<\/strong><\/h2><ul><li>AutoThreshold: Auto, \u201cMonitor\u201d, Off<\/li><\/ul><p>\u00a0<\/p><p><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2020\/10\/Ventricular-Autothreshold-algorithm-3-.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-17712 size-full\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2020\/10\/Ventricular-Autothreshold-algorithm-3-.jpg\" alt=\"\" width=\"1058\" height=\"594\" \/><\/a><\/p><p>\u00a0<\/p><ul><li>minimum ventricular amplitude (Vmin): 1.5 V to 5.0 V (nominal: 2.5V)<\/li><\/ul><p>\u00a0<\/p><p><a href=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2020\/10\/Ventricular-Autothreshold-algorithm-4.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-17713 size-full\" src=\"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2020\/10\/Ventricular-Autothreshold-algorithm-4.jpg\" alt=\"\" width=\"1060\" height=\"602\" \/><\/a><\/p><p>\u00a0<\/p><p>\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-efb4f9b elementor-widget elementor-widget-heading\" data-id=\"efb4f9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Sensing<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3359536 elementor-widget elementor-widget-text-editor\" data-id=\"3359536\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Principle<\/strong><\/p><p>It is possible to program the Atrial and Ventricular Autosensing function with automatic adjustment of A and V sensitivities to variations in the amplitude of detected events. The amplitude of atrial and ventricular events is continuously monitored with automatic cycle-by-cycle adjustment of sensitivities. The amplitude of the signals is averaged over 8 consecutive cycles and the sensitivity is programmed to approximately one third (37.5%) of this average value.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0ed6d75 elementor-widget elementor-widget-image\" data-id=\"0ed6d75\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection13.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection13\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAyNSwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTMucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"700\" height=\"289\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection13.png\" class=\"attachment-large size-large wp-image-5025\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection13.png 700w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection13-300x124.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection13-18x7.png 18w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-af92bef elementor-widget elementor-widget-text-editor\" data-id=\"af92bef\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Following an atrial extrasystole, atrial arrhythmia, or atrial stimulation, atrial sensitivity is forced to 0.4 mV. The amplitude of the PAC is not included in the average. It is replaced by the value 0.4 mV for the calculation of the average amplitude. Autosensing A applies a sensitivity ranging from 0.4 mV to 3 mV.<\/p><p>Similarly, following ventricular pacing, ventricular sensitivity is forced to 1.5 mV in unipolar mode and 2 mV in bipolar mode. Autosensing V applies a sensitivity ranging from 1.5 mV (in unipolar mode) or 2 mV (in bipolar mode) to 6 mV.<\/p><p><strong>Programming<\/strong><\/p><p>Autosensing can be programmed to:<\/p><ol><li>MONITORING, which measures the amplitudes of P waves (sinus and pathological) and R waves (normal and PVC) without adjusting the sensitivity settings, which remain fixed<\/li><li>AUTO, which measures the amplitudes of P waves and R waves with automatic adjustment of sensitivities as described above<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-025af5b elementor-widget elementor-widget-image\" data-id=\"025af5b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection14.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection14\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAyNiwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTQucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"691\" height=\"332\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection14.png\" class=\"attachment-large size-large wp-image-5026\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection14.png 691w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection14-300x144.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection14-18x9.png 18w\" sizes=\"(max-width: 691px) 100vw, 691px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b50187 elementor-widget elementor-widget-text-editor\" data-id=\"1b50187\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>There are a number of restrictions: atrial autosensing can only be programmed to auto if atrial sensitivity is bipolar (if unipolar, only follow mode) and the AV rest delay is greater than 65 ms.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3a4aad elementor-widget elementor-widget-image\" data-id=\"c3a4aad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection15.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection15\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAyNywidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTUucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"469\" height=\"296\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection15.png\" class=\"attachment-large size-large wp-image-5027\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection15.png 469w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection15-300x189.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection15-18x12.png 18w\" sizes=\"(max-width: 469px) 100vw, 469px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03e00ba elementor-widget elementor-widget-text-editor\" data-id=\"03e00ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Stored data<\/strong><\/p><p>The amplitude measurements of detected events are presented in the form of distribution histograms. Detection quality can also be assessed using trend curves for the last 24 hours, where the accuracy (average value) is approximately 8 minutes per point, and trend curves for the last 6 months, where each point represents the average detection value for one day.<\/p><p>In the PM tab of the AIDA Diagnosis screen, clicking on the Autosensing magnifying glass displays the distribution of P waves; clicking on the P\/R Waves button displays the distribution of R waves; clicking on the Track over the last 24 hours button displays the trend curves for P and R waves over the last 24 hours.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8022d4 elementor-widget elementor-widget-image\" data-id=\"b8022d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection16.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection16\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAyOCwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTYucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"685\" height=\"540\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection16.png\" class=\"attachment-large size-large wp-image-5028\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection16.png 685w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection16-300x236.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection16-15x12.png 15w\" sizes=\"(max-width: 685px) 100vw, 685px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54fe02d elementor-widget elementor-widget-text-editor\" data-id=\"54fe02d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>\u201cSinusoidal\u201d P waves represent P wave detections outside the WARAD. \u201cRetrograde\u201d P waves represent P wave detections occurring during the retrograde phase (DDI). P wave detections occurring during the suspected phase are not taken into account.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-654390f elementor-widget elementor-widget-image\" data-id=\"654390f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection17.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection17\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAyOSwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTcucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"690\" height=\"545\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection17.png\" class=\"attachment-large size-large wp-image-5029\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection17.png 690w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection17-300x237.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection17-15x12.png 15w\" sizes=\"(max-width: 690px) 100vw, 690px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-78878a3 elementor-widget elementor-widget-text-editor\" data-id=\"78878a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>PVCs represent R-wave detections whose coupling is 25% shorter than the average of the preceding 4 \u201cnormal\u201d ventricular cycles.<\/p><p>Note that in Symphony, the measurement period represents the last 6 months. In Reply, Reply 200, and Kora 100, the measurement period is equivalent to the last 2 months.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c09a95f elementor-widget elementor-widget-image\" data-id=\"c09a95f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection18.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection18\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAzMCwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTgucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"683\" height=\"545\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection18.png\" class=\"attachment-large size-large wp-image-5030\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection18.png 683w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection18-300x239.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection18-15x12.png 15w\" sizes=\"(max-width: 683px) 100vw, 683px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5ca347c elementor-widget elementor-widget-text-editor\" data-id=\"5ca347c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>In the PM tab of the AIDA Diagnostics screen, clicking on the Probe Measurements magnifying glass displays the atrial detection trend curves; clicking on the V Probe button displays the ventricular detection trend curves.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-072df45 elementor-widget elementor-widget-image\" data-id=\"072df45\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection19.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection19\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAzMSwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMTkucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"691\" height=\"548\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection19.png\" class=\"attachment-large size-large wp-image-5031\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection19.png 691w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection19-300x238.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection19-15x12.png 15w\" sizes=\"(max-width: 691px) 100vw, 691px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-711096e elementor-widget elementor-widget-image\" data-id=\"711096e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection20.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_detection20\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAzMiwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfZGV0ZWN0aW9uMjAucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"688\" height=\"552\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection20.png\" class=\"attachment-large size-large wp-image-5032\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection20.png 688w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection20-300x241.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_detection20-15x12.png 15w\" sizes=\"(max-width: 688px) 100vw, 688px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Microport &#8211; Pacing \/ Sensing Content Atrial pacing No automatic atrial threshold measurement performed by Microport CRM-Sorin pacemakers. Ventricular pacing The Ventricular Autothreshold function is available in all pacing modes, which provide ventricular pacing except in SafeR and Dplus pacing mode. periodical measurement (6 hours, 4 times a day) of the ventricular pacing threshold automatic [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":53,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-3593","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Microport CRM Pacemaker Pacing &amp; Detection | Cardiocases<\/title>\n<meta name=\"description\" content=\"Microport CRM pacemaker pacing &amp; detection \u2014 output, sensitivity, sensing &amp; ECG tracings. For electrophysiologists.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Microport CRM Pacemaker Pacing &amp; Detection | Cardiocases\" \/>\n<meta property=\"og:description\" content=\"Microport CRM pacemaker pacing &amp; detection \u2014 output, sensitivity, sensing &amp; ECG tracings. For electrophysiologists.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/\" \/>\n<meta property=\"og:site_name\" content=\"Cardiocases\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-24T16:46:17+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/\",\"name\":\"Microport CRM Pacemaker Pacing & Detection | Cardiocases\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/microportacademycrm.com\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/Ventricular-Autothreshold-algorithm-1.jpg\",\"datePublished\":\"2025-10-08T18:41:56+00:00\",\"dateModified\":\"2026-01-24T16:46:17+00:00\",\"description\":\"Microport CRM pacemaker pacing & detection \u2014 output, sensitivity, sensing & ECG tracings. For electrophysiologists.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/#primaryimage\",\"url\":\"https:\\\/\\\/microportacademycrm.com\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/Ventricular-Autothreshold-algorithm-1.jpg\",\"contentUrl\":\"https:\\\/\\\/microportacademycrm.com\\\/wp-content\\\/uploads\\\/2020\\\/10\\\/Ventricular-Autothreshold-algorithm-1.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/pacing-detection-microport\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/cardiocases.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pacing &amp; Defibrillation\",\"item\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Devices per company\",\"item\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Microport CRM\",\"item\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Pacing \\\/ Detection Microport\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#website\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/\",\"name\":\"Cardiocases\",\"description\":\"Real cardiac device traces, pacemaker &amp; ICD learning \u2014 built by electrophysiologists\",\"publisher\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/cardiocases.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#organization\",\"name\":\"Cardiocases\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cardiocases_logo.png\",\"contentUrl\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cardiocases_logo.png\",\"width\":1755,\"height\":499,\"caption\":\"Cardiocases\"},\"image\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/cardiocases\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Microport CRM Pacemaker Pacing & Detection | Cardiocases","description":"Microport CRM pacemaker pacing & detection \u2014 output, sensitivity, sensing & ECG tracings. For electrophysiologists.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/","og_locale":"fr_FR","og_type":"article","og_title":"Microport CRM Pacemaker Pacing & Detection | Cardiocases","og_description":"Microport CRM pacemaker pacing & detection \u2014 output, sensitivity, sensing & ECG tracings. For electrophysiologists.","og_url":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/","og_site_name":"Cardiocases","article_modified_time":"2026-01-24T16:46:17+00:00","twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/","url":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/","name":"Microport CRM Pacemaker Pacing & Detection | Cardiocases","isPartOf":{"@id":"https:\/\/cardiocases.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/#primaryimage"},"image":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/#primaryimage"},"thumbnailUrl":"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2020\/10\/Ventricular-Autothreshold-algorithm-1.jpg","datePublished":"2025-10-08T18:41:56+00:00","dateModified":"2026-01-24T16:46:17+00:00","description":"Microport CRM pacemaker pacing & detection \u2014 output, sensitivity, sensing & ECG tracings. For electrophysiologists.","breadcrumb":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/#primaryimage","url":"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2020\/10\/Ventricular-Autothreshold-algorithm-1.jpg","contentUrl":"https:\/\/microportacademycrm.com\/wp-content\/uploads\/2020\/10\/Ventricular-Autothreshold-algorithm-1.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/pacing-detection-microport\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cardiocases.com\/"},{"@type":"ListItem","position":2,"name":"Pacing &amp; Defibrillation","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/"},{"@type":"ListItem","position":3,"name":"Devices per company","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/"},{"@type":"ListItem","position":4,"name":"Microport CRM","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/"},{"@type":"ListItem","position":5,"name":"Pacing \/ Detection Microport"}]},{"@type":"WebSite","@id":"https:\/\/cardiocases.com\/#website","url":"https:\/\/cardiocases.com\/","name":"Cardiocases","description":"Real cardiac device traces, pacemaker &amp; ICD learning \u2014 built by electrophysiologists","publisher":{"@id":"https:\/\/cardiocases.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cardiocases.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/cardiocases.com\/#organization","name":"Cardiocases","url":"https:\/\/cardiocases.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/","url":"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png","contentUrl":"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png","width":1755,"height":499,"caption":"Cardiocases"},"image":{"@id":"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/cardiocases\/"]}]}},"_links":{"self":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/3593","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/comments?post=3593"}],"version-history":[{"count":6,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/3593\/revisions"}],"predecessor-version":[{"id":8739,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/3593\/revisions\/8739"}],"up":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/53"}],"wp:attachment":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/media?parent=3593"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}