{"id":3587,"date":"2025-10-08T18:41:43","date_gmt":"2025-10-08T18:41:43","guid":{"rendered":"https:\/\/cardiocases.com\/?page_id=3587"},"modified":"2025-11-13T14:35:45","modified_gmt":"2025-11-13T14:35:45","slug":"programming-during-exercise-microport","status":"publish","type":"page","link":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/programming-during-exercise-microport\/","title":{"rendered":"Programming during exercise Microport"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"3587\" class=\"elementor elementor-3587\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-00c3cf4 e-con-full e-flex e-con e-parent\" data-id=\"00c3cf4\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3b14fb3 elementor-widget elementor-widget-heading\" data-id=\"3b14fb3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span style=\"font-size: 2rem\">Microport - <\/span>Programming during exercise<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b14874 elementor-toc--minimized-on-tablet elementor-widget elementor-widget-table-of-contents\" data-id=\"9b14874\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;headings_by_tags&quot;:[&quot;h3&quot;,&quot;h4&quot;,&quot;h5&quot;],&quot;exclude_headings_by_selector&quot;:[],&quot;no_headings_message&quot;:&quot;No headings were found on this page.&quot;,&quot;marker_view&quot;:&quot;bullets&quot;,&quot;icon&quot;:{&quot;value&quot;:&quot;fas fa-circle&quot;,&quot;library&quot;:&quot;fa-solid&quot;,&quot;rendered_tag&quot;:&quot;&lt;svg class=\\&quot;e-font-icon-svg e-fas-circle\\&quot; viewBox=\\&quot;0 0 512 512\\&quot; xmlns=\\&quot;http:\\\/\\\/www.w3.org\\\/2000\\\/svg\\&quot;&gt;&lt;path d=\\&quot;M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\\&quot;&gt;&lt;\\\/path&gt;&lt;\\\/svg&gt;&quot;},&quot;minimize_box&quot;:&quot;yes&quot;,&quot;minimized_on&quot;:&quot;tablet&quot;,&quot;hierarchical_view&quot;:&quot;yes&quot;,&quot;min_height&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"table-of-contents.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__header\">\n\t\t\t\t\t\t<h4 class=\"elementor-toc__header-title\">\n\t\t\t\tContent\t\t\t<\/h4>\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--expand\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__9b14874\" aria-expanded=\"true\" aria-label=\"Ouvrir la table des mati\u00e8res\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/div>\n\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--collapse\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__9b14874\" aria-expanded=\"true\" aria-label=\"Fermer la table des mati\u00e8res\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewBox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<div id=\"elementor-toc__9b14874\" class=\"elementor-toc__body\">\n\t\t\t<div class=\"elementor-toc__spinner-container\">\n\t\t\t\t<svg class=\"elementor-toc__spinner eicon-animation-spin e-font-icon-svg e-eicon-loading\" aria-hidden=\"true\" viewBox=\"0 0 1000 1000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M500 975V858C696 858 858 696 858 500S696 142 500 142 142 304 142 500H25C25 237 238 25 500 25S975 237 975 500 763 975 500 975Z\"><\/path><\/svg>\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ec0b867 elementor-widget elementor-widget-heading\" data-id=\"ec0b867\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Frequency control<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-982f107 elementor-widget elementor-widget-text-editor\" data-id=\"982f107\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>The stimulation threshold corresponds to the smallest electrical impulse, delivered outside all natural refractory periods, capable of generating the propagation of a depolarization. It can be measured in voltage (volts) or pulse width (milliseconds).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9f556e9 elementor-widget elementor-widget-image\" data-id=\"9f556e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement14.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_asservissement14\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAwMywidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXNzZXJ2aXNzZW1lbnQxNC5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"361\" height=\"354\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement14.png\" class=\"attachment-large size-large wp-image-5003\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement14.png 361w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement14-300x294.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement14-12x12.png 12w\" sizes=\"(max-width: 361px) 100vw, 361px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9298f6e elementor-widget elementor-widget-text-editor\" data-id=\"9298f6e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>When both sensors are used:<\/p><p>The stimulation frequency is initially controlled by the accelerometer (G), which is the first sensor to react at the start of exercise. Then, minute ventilation (MV) takes over for the entire duration of the effort. Cross-checking of the two sensors: control only continues if both sensors are active. The G sensor detects the end of the effort, and the frequency then gradually returns to the base frequency.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b8df9cf elementor-widget elementor-widget-image\" data-id=\"b8df9cf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement15.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_asservissement15\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAwNCwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXNzZXJ2aXNzZW1lbnQxNS5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"685\" height=\"794\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement15.png\" class=\"attachment-large size-large wp-image-5004\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement15.png 685w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement15-259x300.png 259w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement15-10x12.png 10w\" sizes=\"(max-width: 685px) 100vw, 685px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dca30b8 elementor-widget elementor-widget-text-editor\" data-id=\"dca30b8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Any acceleration detected by one sensor that is not confirmed by the second sensor causes a return to the base frequency. The example above shows an incorrect activation of the G sensor corrected by minute ventilation.<\/p><p>Various parameters can be programmed:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0844acb elementor-widget elementor-widget-image\" data-id=\"0844acb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement17.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_asservissement17\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAwNSwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXNzZXJ2aXNzZW1lbnQxNy5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"585\" height=\"317\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement17.png\" class=\"attachment-large size-large wp-image-5005\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement17.png 585w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement17-300x163.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement17-18x10.png 18w\" sizes=\"(max-width: 585px) 100vw, 585px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea1c14e elementor-widget elementor-widget-text-editor\" data-id=\"ea1c14e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>If Servo Control is set to RR fixed:<\/p><ul><li>The estimated level of the patient&#8217;s physical activity is accessible and programmable<\/li><li>The responsiveness of the system is permanently fixed<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-346a240 elementor-widget elementor-widget-image\" data-id=\"346a240\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement18.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_asservissement18\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAwNiwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXNzZXJ2aXNzZW1lbnQxOC5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"395\" height=\"296\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement18.png\" class=\"attachment-large size-large wp-image-5006\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement18.png 395w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement18-300x225.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement18-16x12.png 16w\" sizes=\"(max-width: 395px) 100vw, 395px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb354db elementor-widget elementor-widget-text-editor\" data-id=\"fb354db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>The Activity setting must correspond to the patient&#8217;s physical activity. A sedentary patient should have their Activity setting set to Low or Very low. The system is then very responsive. Light physical activity causes a rapid increase in the stimulation frequency, close to the maximum stimulation frequency.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-deb33b9 elementor-widget elementor-widget-image\" data-id=\"deb33b9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement19.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_asservissement19\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAwNywidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXNzZXJ2aXNzZW1lbnQxOS5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"701\" height=\"382\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement19.png\" class=\"attachment-large size-large wp-image-5007\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement19.png 701w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement19-300x163.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement19-18x10.png 18w\" sizes=\"(max-width: 701px) 100vw, 701px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bc113d6 elementor-widget elementor-widget-text-editor\" data-id=\"bc113d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>If Servo is set to RR auto (RR = Rate Response):<\/p><p>The estimated level of the patient&#8217;s physical activity is not accessible<br \/><br \/>The responsiveness of the system automatically adjusts according to the patient&#8217;s physical activity<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d6e3668 elementor-widget elementor-widget-image\" data-id=\"d6e3668\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement20.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_asservissement20\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAwOCwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXNzZXJ2aXNzZW1lbnQyMC5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"402\" height=\"162\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement20.png\" class=\"attachment-large size-large wp-image-5008\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement20.png 402w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement20-300x121.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement20-18x7.png 18w\" sizes=\"(max-width: 402px) 100vw, 402px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e5642d2 elementor-widget elementor-widget-text-editor\" data-id=\"e5642d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>The system continuously assesses the patient&#8217;s level of physical activity. In the following example, the level of ventilation during exercise has been increased following greater exertion in terms of ventilation. Any exertion above the current level of ventilation leads to an increase in the Activity parameter (i.e., it tends toward the Very high value). Conversely, the level of ventilation during exertion is automatically reduced by a few percent each day. Thus, a patient who becomes inactive will see their Activity parameter spontaneously tend towards the Very low value within a few days. The level of ventilation at rest corresponds to the average level of ventilation during the day.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0ad55e4 elementor-widget elementor-widget-image\" data-id=\"0ad55e4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement21.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_asservissement21\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NTAwOSwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXNzZXJ2aXNzZW1lbnQyMS5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"708\" height=\"381\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement21.png\" class=\"attachment-large size-large wp-image-5009\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement21.png 708w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement21-300x161.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement21-18x10.png 18w\" sizes=\"(max-width: 708px) 100vw, 708px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Microport &#8211; Programming during exercise Content Frequency control The stimulation threshold corresponds to the smallest electrical impulse, delivered outside all natural refractory periods, capable of generating the propagation of a depolarization. It can be measured in voltage (volts) or pulse width (milliseconds). When both sensors are used: The stimulation frequency is initially controlled by the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":53,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-3587","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Microport CRM Pacemaker Exercise Programming | Cardiocases<\/title>\n<meta name=\"description\" content=\"Program Microport CRM pacemakers for exercise \u2014 rate response, accelerometer settings &amp; ECG tracings.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/programming-during-exercise-microport\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Microport CRM Pacemaker Exercise Programming | Cardiocases\" \/>\n<meta property=\"og:description\" content=\"Program Microport CRM pacemakers for exercise \u2014 rate response, accelerometer settings &amp; ECG tracings.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/programming-during-exercise-microport\/\" \/>\n<meta property=\"og:site_name\" content=\"Cardiocases\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-13T14:35:45+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement14.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/programming-during-exercise-microport\\\/\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/programming-during-exercise-microport\\\/\",\"name\":\"Microport CRM Pacemaker Exercise Programming | Cardiocases\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/programming-during-exercise-microport\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/programming-during-exercise-microport\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/pm_19_situations_asservissement14.png\",\"datePublished\":\"2025-10-08T18:41:43+00:00\",\"dateModified\":\"2025-11-13T14:35:45+00:00\",\"description\":\"Program Microport CRM pacemakers for exercise \u2014 rate response, accelerometer settings & ECG tracings.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/programming-during-exercise-microport\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/programming-during-exercise-microport\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/programming-during-exercise-microport\\\/#primaryimage\",\"url\":\"http:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/pm_19_situations_asservissement14.png\",\"contentUrl\":\"http:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/pm_19_situations_asservissement14.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/programming-during-exercise-microport\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/cardiocases.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pacing &amp; Defibrillation\",\"item\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Devices per company\",\"item\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Microport CRM\",\"item\":\"https:\\\/\\\/cardiocases.com\\\/pacing-defibrillation\\\/devices-per-company\\\/microport-crm\\\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Programming during exercise Microport\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#website\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/\",\"name\":\"Cardiocases\",\"description\":\"Real cardiac device traces, pacemaker &amp; ICD learning \u2014 built by electrophysiologists\",\"publisher\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/cardiocases.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#organization\",\"name\":\"Cardiocases\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cardiocases_logo.png\",\"contentUrl\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cardiocases_logo.png\",\"width\":1755,\"height\":499,\"caption\":\"Cardiocases\"},\"image\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/cardiocases\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Microport CRM Pacemaker Exercise Programming | Cardiocases","description":"Program Microport CRM pacemakers for exercise \u2014 rate response, accelerometer settings & ECG tracings.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/programming-during-exercise-microport\/","og_locale":"fr_FR","og_type":"article","og_title":"Microport CRM Pacemaker Exercise Programming | Cardiocases","og_description":"Program Microport CRM pacemakers for exercise \u2014 rate response, accelerometer settings & ECG tracings.","og_url":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/programming-during-exercise-microport\/","og_site_name":"Cardiocases","article_modified_time":"2025-11-13T14:35:45+00:00","og_image":[{"url":"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement14.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/programming-during-exercise-microport\/","url":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/programming-during-exercise-microport\/","name":"Microport CRM Pacemaker Exercise Programming | Cardiocases","isPartOf":{"@id":"https:\/\/cardiocases.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/programming-during-exercise-microport\/#primaryimage"},"image":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/programming-during-exercise-microport\/#primaryimage"},"thumbnailUrl":"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement14.png","datePublished":"2025-10-08T18:41:43+00:00","dateModified":"2025-11-13T14:35:45+00:00","description":"Program Microport CRM pacemakers for exercise \u2014 rate response, accelerometer settings & ECG tracings.","breadcrumb":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/programming-during-exercise-microport\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/programming-during-exercise-microport\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/programming-during-exercise-microport\/#primaryimage","url":"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement14.png","contentUrl":"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_asservissement14.png"},{"@type":"BreadcrumbList","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/programming-during-exercise-microport\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cardiocases.com\/"},{"@type":"ListItem","position":2,"name":"Pacing &amp; Defibrillation","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/"},{"@type":"ListItem","position":3,"name":"Devices per company","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/"},{"@type":"ListItem","position":4,"name":"Microport CRM","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/"},{"@type":"ListItem","position":5,"name":"Programming during exercise Microport"}]},{"@type":"WebSite","@id":"https:\/\/cardiocases.com\/#website","url":"https:\/\/cardiocases.com\/","name":"Cardiocases","description":"Real cardiac device traces, pacemaker &amp; ICD learning \u2014 built by electrophysiologists","publisher":{"@id":"https:\/\/cardiocases.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cardiocases.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/cardiocases.com\/#organization","name":"Cardiocases","url":"https:\/\/cardiocases.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/","url":"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png","contentUrl":"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png","width":1755,"height":499,"caption":"Cardiocases"},"image":{"@id":"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/cardiocases\/"]}]}},"_links":{"self":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/3587","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/comments?post=3587"}],"version-history":[{"count":0,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/3587\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/53"}],"wp:attachment":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/media?parent=3587"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}