{"id":3584,"date":"2025-10-08T18:41:14","date_gmt":"2025-10-08T18:41:14","guid":{"rendered":"https:\/\/cardiocases.com\/?page_id=3584"},"modified":"2025-11-15T21:16:25","modified_gmt":"2025-11-15T21:16:25","slug":"atrial-arrhythmia-management-microport","status":"publish","type":"page","link":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/","title":{"rendered":"Gestion de l'arythmie auriculaire"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"3584\" class=\"elementor elementor-3584\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-fb22c24 e-con-full e-flex e-con e-parent\" data-id=\"fb22c24\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-a547cfb elementor-widget elementor-widget-heading\" data-id=\"a547cfb\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\"><span style=\"font-size: 2rem\">Microport - <\/span>Gestion de l'arythmie auriculaire<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73e1385 elementor-toc--minimized-on-tablet elementor-widget elementor-widget-table-of-contents\" data-id=\"73e1385\" data-element_type=\"widget\" data-settings=\"{&quot;headings_by_tags&quot;:[&quot;h3&quot;,&quot;h4&quot;,&quot;h5&quot;],&quot;exclude_headings_by_selector&quot;:[],&quot;no_headings_message&quot;:&quot;No headings were found on this page.&quot;,&quot;marker_view&quot;:&quot;bullets&quot;,&quot;icon&quot;:{&quot;value&quot;:&quot;fas fa-circle&quot;,&quot;library&quot;:&quot;fa-solid&quot;,&quot;rendered_tag&quot;:&quot;&lt;svg class=\\&quot;e-font-icon-svg e-fas-circle\\&quot; viewBox=\\&quot;0 0 512 512\\&quot; xmlns=\\&quot;http:\\\/\\\/www.w3.org\\\/2000\\\/svg\\&quot;&gt;&lt;path d=\\&quot;M256 8C119 8 8 119 8 256s111 248 248 248 248-111 248-248S393 8 256 8z\\&quot;&gt;&lt;\\\/path&gt;&lt;\\\/svg&gt;&quot;},&quot;minimize_box&quot;:&quot;yes&quot;,&quot;minimized_on&quot;:&quot;tablet&quot;,&quot;hierarchical_view&quot;:&quot;yes&quot;,&quot;min_height&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"table-of-contents.default\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__header\">\n\t\t\t\t\t\t<h4 class=\"elementor-toc__header-title\">\n\t\t\t\tG\u00e9n\u00e9ralit\u00e9s\t\t\t<\/h4>\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--expand\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__73e1385\" aria-expanded=\"true\" aria-label=\"Ouvrir la table des mati\u00e8res\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-down\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M207.029 381.476L12.686 187.132c-9.373-9.373-9.373-24.569 0-33.941l22.667-22.667c9.357-9.357 24.522-9.375 33.901-.04L224 284.505l154.745-154.021c9.379-9.335 24.544-9.317 33.901.04l22.667 22.667c9.373 9.373 9.373 24.569 0 33.941L240.971 381.476c-9.373 9.372-24.569 9.372-33.942 0z\"><\/path><\/svg><\/div>\n\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--collapse\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__73e1385\" aria-expanded=\"true\" aria-label=\"Fermer la table des mati\u00e8res\"><svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fas-chevron-up\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M240.971 130.524l194.343 194.343c9.373 9.373 9.373 24.569 0 33.941l-22.667 22.667c-9.357 9.357-24.522 9.375-33.901.04L224 227.495 69.255 381.516c-9.379 9.335-24.544 9.317-33.901-.04l-22.667-22.667c-9.373-9.373-9.373-24.569 0-33.941L207.03 130.525c9.372-9.373 24.568-9.373 33.941-.001z\"><\/path><\/svg><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<div id=\"elementor-toc__73e1385\" class=\"elementor-toc__body\">\n\t\t\t<div class=\"elementor-toc__spinner-container\">\n\t\t\t\t<svg class=\"elementor-toc__spinner eicon-animation-spin e-font-icon-svg e-eicon-loading\" aria-hidden=\"true\" viewbox=\"0 0 1000 1000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M500 975V858C696 858 858 696 858 500S696 142 500 142 142 304 142 500H25C25 237 238 25 500 25S975 237 975 500 763 975 500 975Z\"><\/path><\/svg>\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7301f54 elementor-widget elementor-widget-heading\" data-id=\"7301f54\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Algorithme de changement de mode<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ca876cc elementor-widget elementor-widget-text-editor\" data-id=\"ca876cc\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Principe de l'algorithme de commutation de mode<\/strong><\/p><p>L'identification de l'arythmie est bas\u00e9e sur :<\/p><ul><li>une fr\u00e9quence atriale au-dessus de laquelle le stimulateur passe automatiquement en mode DDI (le repli n'a lieu que si la fr\u00e9quence atriale d\u00e9passe 120 min-1 ; ce param\u00e8tre ne peut pas \u00eatre modifi\u00e9).<\/li><li>d\u00e9tection d'une acc\u00e9l\u00e9ration soudaine du rythme auriculaire sur la base d'une fen\u00eatre dynamique de pr\u00e9maturit\u00e9 = Atrial Rhythm Acceleration Detection (WARAD)<\/li><li>confirmation bas\u00e9e sur un traitement statistique de l'arythmie auriculaire en cas de sous-d\u00e9tection auriculaire<\/li><\/ul><p>\u00a0<\/p><p><strong>WARAD<\/strong><\/p><p>WARAD est d\u00e9clench\u00e9 \u00e0 chaque \u00e9v\u00e9nement auriculaire normal stimul\u00e9 ou d\u00e9tect\u00e9. Sa dur\u00e9e, calcul\u00e9e dynamiquement, d\u00e9pend de la fr\u00e9quence sinusale.<\/p><p>Lorsque le rythme sinusal est inf\u00e9rieur \u00e0 80 min-1, le WARAD repr\u00e9sente 62,5% de l'intervalle P-P pr\u00e9c\u00e9dent.<\/p><p>Lorsque le rythme sinusal est sup\u00e9rieur (ou \u00e9gal) \u00e0 80 min-1, le WARAD repr\u00e9sente 75% de l'intervalle P-P pr\u00e9c\u00e9dent.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-de8ba01 elementor-widget elementor-widget-image\" data-id=\"de8ba01\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a17.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_a17\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk1NCwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2ExNy5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"501\" height=\"301\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a17.png\" class=\"attachment-large size-large wp-image-4954\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a17.png 501w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a17-300x180.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a17-18x12.png 18w\" sizes=\"(max-width: 501px) 100vw, 501px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e8d5c7 elementor-widget elementor-widget-text-editor\" data-id=\"3e8d5c7\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Phase de suspicion d\u2019arythmie atriale (N:1)<\/strong><\/p><p>Au d\u00e9but d'un rythme auriculaire rapide, un court d\u00e9lai AV peut \u00eatre d\u00e9clench\u00e9 sur certaines d\u00e9tections d'ondes P dans WARAD si et seulement si l'intervalle R-V ou V-V qui serait appliqu\u00e9 est sup\u00e9rieur \u00e0 500 ms. Ceci permet d'\u00e9viter une stimulation ventriculaire trop rapide au d\u00e9but de l'\u00e9pisode avant de passer en mode asynchrone. Pendant cette phase de suspicion de trouble du rythme auriculaire, tous les \u00e9v\u00e9nements auriculaires d\u00e9tect\u00e9s sont marqu\u00e9s avec des marqueurs de p\u00e9riode r\u00e9fractaire (petits \u201cp\u201d). La valeur WARAD est alors fix\u00e9e \u00e0 la valeur WARAD qui a d\u00e9tect\u00e9 le tout premier PAC et ne peut pas d\u00e9passer 500 ms. Le court d\u00e9lai AV qui peut \u00eatre d\u00e9clench\u00e9 apr\u00e8s certaines d\u00e9tections d'ondes P dans WARAD est de 30 ms (non programmable).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb6df30 elementor-widget elementor-widget-image\" data-id=\"cb6df30\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a18.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_a18\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk1NSwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2ExOC5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"723\" height=\"633\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a18.png\" class=\"attachment-large size-large wp-image-4955\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a18.png 723w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a18-300x263.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a18-14x12.png 14w\" sizes=\"(max-width: 723px) 100vw, 723px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9bce167 elementor-widget elementor-widget-text-editor\" data-id=\"9bce167\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Les cycles ventriculaires avec au moins une d\u00e9tection auriculaire dans le WARAD sont consid\u00e9r\u00e9s comme \u201csuspects\u201d.\u201d<\/p><p><strong>Fonctionnement de l'algorithme de changement de mode<\/strong><\/p><p>La fonction de secours se compose de trois phases distinctes : une phase de suspicion\/confirmation, une phase de dissociation et une phase de r\u00e9association.<\/p><p><strong>Phase de suspicion\/confirmation<\/strong><\/p><p>D\u00e8s qu'un cycle ventriculaire avec suspicion d'arythmie auriculaire est d\u00e9tect\u00e9, l'algorithme de repli commence une analyse de 32 cycles ventriculaires (r\u00e9p\u00e9t\u00e9e par blocs de 32 cycles ventriculaires si n\u00e9cessaire).<\/p><p>L'arythmie auriculaire est confirm\u00e9e si l'un des deux crit\u00e8res suivants est atteint:<\/p><ol><li>28 cycles ventriculaires ou plus sont en suspicion au cours des 32 derniers cycles ventriculaires (crit\u00e8re primaire)<\/li><li>Une fois un des crit\u00e8res de Repli atteint, le mode de stimulation commute d\u2019un mode synchrone (DDD ou AAI-SafeR) vers un mode asynchrone (DDI). La fr\u00e9quence de stimulation ventriculaire diminue progressivement (l'intervalle d'\u00e9chappement ventriculaire augmente de 30 ms tous les 12 cycles) vers la fr\u00e9quence de base, la fr\u00e9quence asservie, ou la fr\u00e9quence de repos.<\/li><\/ol><p>Le crit\u00e8re principal est g\u00e9n\u00e9ralement rempli en 15 secondes environ. Le crit\u00e8re secondaire peut permettre un repli en cas de sous-d\u00e9tection auriculaire.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-41a6b4d elementor-widget elementor-widget-heading\" data-id=\"41a6b4d\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Fonctionnement de l'algorithme de changement de mode<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9c1e6ea elementor-widget elementor-widget-text-editor\" data-id=\"9c1e6ea\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>La fonction de changement de mode se compose de trois phases distinctes : une phase de suspicion\/confirmation, une phase de dissociation et une phase de r\u00e9association.<\/p><p><strong>Phase de suspicion\/confirmation<\/strong><\/p><p>D\u00e8s qu'un cycle ventriculaire avec suspicion d'arythmie auriculaire est d\u00e9tect\u00e9, l'algorithme de repli commence une analyse de 32 cycles ventriculaires (r\u00e9p\u00e9t\u00e9e par blocs de 32 cycles ventriculaires si n\u00e9cessaire).<\/p><p>L'arythmie auriculaire est confirm\u00e9e si l'un des deux crit\u00e8res suivants est atteint:<\/p><ol><li>28 cycles ventriculaires ou plus sont en suspicion au cours des 32 derniers cycles ventriculaires (crit\u00e8re primaire)<\/li><li>Une fois un des crit\u00e8res de Repli atteint, le mode de stimulation commute d\u2019un mode synchrone (DDD ou AAI-SafeR) vers un mode asynchrone (DDI). La fr\u00e9quence de stimulation ventriculaire diminue progressivement (l'intervalle d'\u00e9chappement ventriculaire augmente de 30 ms tous les 12 cycles) vers la fr\u00e9quence de base, la fr\u00e9quence asservie, ou la fr\u00e9quence de repos.<\/li><\/ol><p>Le crit\u00e8re principal est g\u00e9n\u00e9ralement rempli en 15 secondes environ. Le crit\u00e8re secondaire peut permettre un repli en cas de sous-d\u00e9tection auriculaire.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac90608 elementor-widget elementor-widget-image\" data-id=\"ac90608\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a19.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_a19\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk1NiwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2ExOS5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"502\" height=\"199\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a19.png\" class=\"attachment-large size-large wp-image-4956\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a19.png 502w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a19-300x119.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a19-18x7.png 18w\" sizes=\"(max-width: 502px) 100vw, 502px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4f299eb elementor-widget elementor-widget-text-editor\" data-id=\"4f299eb\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Phase de dissociation<\/strong><\/p><p>Lorsque l'un des crit\u00e8res de retraite est rempli, le mode de stimulation passe d'un mode synchrone (DDD ou AAI-SafeR) \u00e0 un mode asynchrone (DDI). La fr\u00e9quence de stimulation ventriculaire diminue progressivement (l'intervalle d'\u00e9chappement ventriculaire augmente de 30 ms tous les 12 cycles) vers la fr\u00e9quence de base, la fr\u00e9quence cible ou la fr\u00e9quence de repos.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a10023d elementor-widget elementor-widget-image\" data-id=\"a10023d\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a20.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_a20\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk1NywidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2EyMC5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"534\" height=\"307\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a20.png\" class=\"attachment-large size-large wp-image-4957\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a20.png 534w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a20-300x172.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a20-18x10.png 18w\" sizes=\"(max-width: 534px) 100vw, 534px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b79b69d elementor-widget elementor-widget-text-editor\" data-id=\"b79b69d\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Phase de r\u00e9association<\/strong><\/p><p>D\u00e8s que l'arythmie auriculaire cesse et que le rythme sinusal reprend, la fr\u00e9quence de stimulation ventriculaire est progressivement ajust\u00e9e pour correspondre au rythme sinusal. La r\u00e9association A-V ne se produit que si les rythmes auriculaires et ventriculaires sont inf\u00e9rieurs \u00e0 110 min-1. Un RetroPwatch de 500 ms est appliqu\u00e9 au premier ventricule r\u00e9associ\u00e9 pour emp\u00eacher l'apparition d'une PMT.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef8b4f2 elementor-widget elementor-widget-image\" data-id=\"ef8b4f2\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a21.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_a21\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk1OCwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2EyMS5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"579\" height=\"306\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a21.png\" class=\"attachment-large size-large wp-image-4958\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a21.png 579w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a21-300x159.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a21-18x10.png 18w\" sizes=\"(max-width: 579px) 100vw, 579px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9827657 elementor-widget elementor-widget-text-editor\" data-id=\"9827657\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Programmation des commutateurs de mode<\/strong><\/p><p>La fonction est activ\u00e9e par d\u00e9faut.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0888503 elementor-widget elementor-widget-image\" data-id=\"0888503\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a22.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_a22\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk1OSwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2EyMi5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"561\" height=\"461\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a22.png\" class=\"attachment-large size-large wp-image-4959\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a22.png 561w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a22-300x247.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a22-15x12.png 15w\" sizes=\"(max-width: 561px) 100vw, 561px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eadf3e3 elementor-widget elementor-widget-text-editor\" data-id=\"eadf3e3\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Interrogations des m\u00e9moires<\/strong><\/p><p>Sur l'\u00e9cran de synth\u00e8se, un commentaire est not\u00e9 indiquant :<\/p><ol><li>Le temps pass\u00e9 \u00e0 se retirer (en %)<\/li><li>La fr\u00e9quence ventriculaire pendant les p\u00e9riodes de sevrage<\/li><\/ol>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dde15d8 elementor-widget elementor-widget-image\" data-id=\"dde15d8\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a23.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_a23\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk2MCwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2EyMy5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"526\" height=\"436\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a23.png\" class=\"attachment-large size-large wp-image-4960\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a23.png 526w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a23-300x249.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a23-14x12.png 14w\" sizes=\"(max-width: 526px) 100vw, 526px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5fd2139 elementor-widget elementor-widget-text-editor\" data-id=\"5fd2139\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Une autre fa\u00e7on d'acc\u00e9der aux \u00e9pisodes en replay est de cliquer sur Diagnos. AIDA, puis sur l'onglet Arythmie.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-21610c2 elementor-widget elementor-widget-image\" data-id=\"21610c2\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a24.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_a24\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk2MSwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2EyNC5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"687\" height=\"950\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a24.png\" class=\"attachment-large size-large wp-image-4961\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a24.png 687w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a24-217x300.png 217w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a24-9x12.png 9w\" sizes=\"(max-width: 687px) 100vw, 687px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0e659cc elementor-widget elementor-widget-image\" data-id=\"0e659cc\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a25.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_a25\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk2MiwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2EyNS5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"641\" height=\"511\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a25.png\" class=\"attachment-large size-large wp-image-4962\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a25.png 641w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a25-300x239.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a25-15x12.png 15w\" sizes=\"(max-width: 641px) 100vw, 641px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bdf44b4 elementor-widget elementor-widget-text-editor\" data-id=\"bdf44b4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Une vue hebdomadaire ou quotidienne d\u00e9taill\u00e9e montre : la dur\u00e9e de la FA (temps de recul), le nombre d'\u00e9pisodes de FA, la fr\u00e9quence ventriculaire et le pourcentage de d\u00e9tections ventriculaires.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24afd17 elementor-widget elementor-widget-image\" data-id=\"24afd17\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a26.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_a26\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk2MywidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2EyNi5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"698\" height=\"545\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a26.png\" class=\"attachment-large size-large wp-image-4963\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a26.png 698w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a26-300x234.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a26-15x12.png 15w\" sizes=\"(max-width: 698px) 100vw, 698px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cf5144d elementor-widget elementor-widget-image\" data-id=\"cf5144d\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a27.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_a27\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk2NCwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2EyNy5wbmcifQ%3D%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"686\" height=\"544\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a27.png\" class=\"attachment-large size-large wp-image-4964\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a27.png 686w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a27-300x238.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a27-15x12.png 15w\" sizes=\"(max-width: 686px) 100vw, 686px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a503993 elementor-widget elementor-widget-heading\" data-id=\"a503993\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Gestion du flutter<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14989f4 elementor-widget elementor-widget-text-editor\" data-id=\"14989f4\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Il n'existe pas d'algorithme de ce type ; lorsqu'un flutter 2\/1 se produit, il est n\u00e9cessaire de raccourcir la dur\u00e9e de la p\u00e9riode de suppression auriculaire apr\u00e8s la stimulation ventriculaire.\u00a0<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-11cef2c elementor-widget elementor-widget-heading\" data-id=\"11cef2c\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Algorithme de pr\u00e9vention de la fibrillation auriculaire<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a6fd617 elementor-widget elementor-widget-text-editor\" data-id=\"a6fd617\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Overdrive du rythme sinusal<\/strong><\/p><p>L'objectif est d'assurer une stimulation auriculaire permanente l\u00e9g\u00e8rement sup\u00e9rieure au rythme sinusal pour pr\u00e9venir l'apparition de la FA en r\u00e9duisant l'intervalle de stimulation auriculaire (-50 ms) apr\u00e8s la d\u00e9tection d'ondes P non acc\u00e9l\u00e9r\u00e9es (d\u00e9tection en dehors de la fen\u00eatre INOV (et en dehors de la fen\u00eatre DARA)). Cette fonction est limit\u00e9e par une fr\u00e9quence d'overdrive maximale programmable. Par d\u00e9faut, cet algorithme est inactif.<\/p><p>Pour \u00e9viter une acc\u00e9l\u00e9ration inappropri\u00e9e des extrasystoles auriculaires tardives, il existe une fen\u00eatre sp\u00e9cifique (la fen\u00eatre INOV, INappropriate OVerdriving). La valeur de cette fen\u00eatre de surveillance des AES tardifs est bas\u00e9e sur le temps de conduction AV ou PR et sur la fr\u00e9quence maximale de l'overdrive. Si une onde P est d\u00e9tect\u00e9e dans la fen\u00eatre INOV, la fonction de surmultiplication du rythme sinusal est inhib\u00e9e.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a312559 elementor-widget elementor-widget-image\" data-id=\"a312559\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa11.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_fa11\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk2NSwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2ZhMTEucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"659\" height=\"293\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa11.png\" class=\"attachment-large size-large wp-image-4965\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa11.png 659w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa11-300x133.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa11-18x8.png 18w\" sizes=\"(max-width: 659px) 100vw, 659px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0138184 elementor-widget elementor-widget-text-editor\" data-id=\"0138184\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Apr\u00e8s 16 cycles \u201csurmultipli\u00e9s\u201d, la fr\u00e9quence de stimulation diminue avec le lissage programm\u00e9 (tr\u00e8s lent par d\u00e9faut). La fr\u00e9quence maximale d'overdrive est programm\u00e9e ici \u00e0 100 min-1.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-468ee81 elementor-widget elementor-widget-image\" data-id=\"468ee81\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa12.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_fa12\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk2NiwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2ZhMTIucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"577\" height=\"349\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa12.png\" class=\"attachment-large size-large wp-image-4966\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa12.png 577w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa12-300x181.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa12-18x12.png 18w\" sizes=\"(max-width: 577px) 100vw, 577px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1da5e4e elementor-widget elementor-widget-image\" data-id=\"1da5e4e\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa13.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_fa13\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk2NywidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2ZhMTMucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"636\" height=\"930\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa13.png\" class=\"attachment-large size-large wp-image-4967\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa13.png 636w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa13-205x300.png 205w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa13-8x12.png 8w\" sizes=\"(max-width: 636px) 100vw, 636px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03e596a elementor-widget elementor-widget-text-editor\" data-id=\"03e596a\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>\u00c9limination des pauses sur le PAC<\/strong><\/p><p>L'objectif de cet algorithme est de pr\u00e9venir l'apparition d'une fibrillation auriculaire sur une succession de cycles auriculaires courts (extrasystole) et longs (pause compensatoire).<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a132d63 elementor-widget elementor-widget-image\" data-id=\"a132d63\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa14.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_fa14\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk2OCwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2ZhMTQucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"678\" height=\"280\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa14.png\" class=\"attachment-large size-large wp-image-4968\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa14.png 678w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa14-300x124.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa14-18x7.png 18w\" sizes=\"(max-width: 678px) 100vw, 678px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c67306 elementor-widget elementor-widget-text-editor\" data-id=\"4c67306\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>En cas d'AES \u201ctardif\u201d isol\u00e9 (avec un couplage sup\u00e9rieur \u00e0 50% du dernier intervalle P-P), l'algorithme d\u00e9clenche un d\u00e9lai AV automatique et un intervalle d'\u00e9chappement interm\u00e9diaire.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61902d4 elementor-widget elementor-widget-image\" data-id=\"61902d4\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa15.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_fa15\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk2OSwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2ZhMTUucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"659\" height=\"328\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa15.png\" class=\"attachment-large size-large wp-image-4969\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa15.png 659w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa15-300x149.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa15-18x9.png 18w\" sizes=\"(max-width: 659px) 100vw, 659px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db98da1 elementor-widget elementor-widget-text-editor\" data-id=\"db98da1\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p><strong>Acc\u00e9l\u00e9ration de fr\u00e9quence sur ESA<\/strong><\/p><p>Pour r\u00e9duire le nombre d'extrasystoles, cet algorithme permet une acc\u00e9l\u00e9ration temporaire de la fr\u00e9quence (~ 5 min-1) (24 cycles) apr\u00e8s de fr\u00e9quentes extrasystoles auriculaires isol\u00e9es (s\u00e9par\u00e9es par un maximum de 15 cycles auriculaires normaux). Par d\u00e9faut, cet algorithme est inactif. La phase d'acc\u00e9l\u00e9ration est arr\u00eat\u00e9e si le taux d'acc\u00e9l\u00e9ration maximum est atteint ou si le compteur PAC maximum est atteint. Ces deux crit\u00e8res d'arr\u00eat ne sont pas programmables. Cet arr\u00eat est suivi d'un lissage \u201cd\u00e9finitif\u201d sur le rythme de base.<\/p><p>La fr\u00e9quence d'acc\u00e9l\u00e9ration maximale est calcul\u00e9e comme suit : si la fr\u00e9quence auriculaire est inf\u00e9rieure \u00e0 90 min-1, l'intervalle d'\u00e9chappement repr\u00e9sente 75% de la moyenne des huit derniers intervalles P-P juste avant le premier PAC. Sinon, l'intervalle d'\u00e9chappement repr\u00e9sente 75% de la moyenne des huit derniers intervalles P-P juste avant le premier PAC + 50 ms.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3908d16 elementor-widget elementor-widget-image\" data-id=\"3908d16\" data-element_type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa16.png\" data-elementor-open-lightbox=\"yes\" data-elementor-lightbox-title=\"pm_19_situations_arythmies_fa16\" data-e-action-hash=\"#elementor-action%3Aaction%3Dlightbox%26settings%3DeyJpZCI6NDk3MCwidXJsIjoiaHR0cHM6XC9cL2NhcmRpb2Nhc2VzLmNvbVwvd3AtY29udGVudFwvdXBsb2Fkc1wvMjAyNVwvMTFcL3BtXzE5X3NpdHVhdGlvbnNfYXJ5dGhtaWVzX2ZhMTYucG5nIn0%3D\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"661\" height=\"595\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa16.png\" class=\"attachment-large size-large wp-image-4970\" alt=\"\" srcset=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa16.png 661w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa16-300x270.png 300w, https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_fa16-13x12.png 13w\" sizes=\"(max-width: 661px) 100vw, 661px\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Microport &#8211; Atrial arrhythmia management Content Mode-switch algorithm Principle of the mode-switch algorithm Arrhythmia identification is based on: an atrial rate above which the pacemaker automatically switches to DDI mode (fallback only occurs if the atrial rate exceeds 120 min-1; this parameter cannot be modified) detection of a sudden acceleration in atrial rhythm based on [&hellip;]<\/p>","protected":false},"author":1,"featured_media":0,"parent":53,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-3584","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Microport CRM Atrial Arrhythmia Management | Cardiocases<\/title>\n<meta name=\"description\" content=\"Microport CRM mode switch &amp; atrial arrhythmia management \u2014 programming, ECG recognition &amp; tips.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Microport CRM Atrial Arrhythmia Management | Cardiocases\" \/>\n<meta property=\"og:description\" content=\"Microport CRM mode switch &amp; atrial arrhythmia management \u2014 programming, ECG recognition &amp; tips.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/\" \/>\n<meta property=\"og:site_name\" content=\"Cardiocases\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-15T21:16:25+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a17.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/\",\"url\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/\",\"name\":\"Microport CRM Atrial Arrhythmia Management | Cardiocases\",\"isPartOf\":{\"@id\":\"https:\/\/cardiocases.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/#primaryimage\"},\"thumbnailUrl\":\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a17.png\",\"datePublished\":\"2025-10-08T18:41:14+00:00\",\"dateModified\":\"2025-11-15T21:16:25+00:00\",\"description\":\"Microport CRM mode switch & atrial arrhythmia management \u2014 programming, ECG recognition & tips.\",\"breadcrumb\":{\"@id\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/#primaryimage\",\"url\":\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a17.png\",\"contentUrl\":\"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a17.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/cardiocases.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pacing &amp; Defibrillation\",\"item\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Devices per company\",\"item\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Microport CRM\",\"item\":\"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"Atrial arrhythmia management\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/cardiocases.com\/#website\",\"url\":\"https:\/\/cardiocases.com\/\",\"name\":\"Cardiocases\",\"description\":\"Real cardiac device traces, pacemaker &amp; ICD learning \u2014 built by electrophysiologists\",\"publisher\":{\"@id\":\"https:\/\/cardiocases.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/cardiocases.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/cardiocases.com\/#organization\",\"name\":\"Cardiocases\",\"url\":\"https:\/\/cardiocases.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png\",\"contentUrl\":\"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png\",\"width\":1755,\"height\":499,\"caption\":\"Cardiocases\"},\"image\":{\"@id\":\"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/cardiocases\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Microport CRM Atrial Arrhythmia Management | Cardiocases","description":"Microport CRM mode switch & atrial arrhythmia management \u2014 programming, ECG recognition & tips.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/","og_locale":"fr_FR","og_type":"article","og_title":"Microport CRM Atrial Arrhythmia Management | Cardiocases","og_description":"Microport CRM mode switch & atrial arrhythmia management \u2014 programming, ECG recognition & tips.","og_url":"https:\/\/cardiocases.com\/fr\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/","og_site_name":"Cardiocases","article_modified_time":"2025-11-15T21:16:25+00:00","og_image":[{"url":"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a17.png","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/","url":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/","name":"Microport CRM Atrial Arrhythmia Management | Cardiocases","isPartOf":{"@id":"https:\/\/cardiocases.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/#primaryimage"},"image":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/#primaryimage"},"thumbnailUrl":"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a17.png","datePublished":"2025-10-08T18:41:14+00:00","dateModified":"2025-11-15T21:16:25+00:00","description":"Microport CRM mode switch & atrial arrhythmia management \u2014 programming, ECG recognition & tips.","breadcrumb":{"@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/#primaryimage","url":"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a17.png","contentUrl":"http:\/\/cardiocases.com\/wp-content\/uploads\/2025\/11\/pm_19_situations_arythmies_a17.png"},{"@type":"BreadcrumbList","@id":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/atrial-arrhythmia-management-microport\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cardiocases.com\/"},{"@type":"ListItem","position":2,"name":"Pacing &amp; Defibrillation","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/"},{"@type":"ListItem","position":3,"name":"Devices per company","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/"},{"@type":"ListItem","position":4,"name":"Microport CRM","item":"https:\/\/cardiocases.com\/pacing-defibrillation\/devices-per-company\/microport-crm\/"},{"@type":"ListItem","position":5,"name":"Atrial arrhythmia management"}]},{"@type":"WebSite","@id":"https:\/\/cardiocases.com\/#website","url":"https:\/\/cardiocases.com\/","name":"Cardiocases","description":"Real cardiac device traces, pacemaker &amp; ICD learning \u2014 built by electrophysiologists","publisher":{"@id":"https:\/\/cardiocases.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cardiocases.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/cardiocases.com\/#organization","name":"Cardiocases","url":"https:\/\/cardiocases.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/","url":"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png","contentUrl":"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png","width":1755,"height":499,"caption":"Cardiocases"},"image":{"@id":"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/cardiocases\/"]}]}},"_links":{"self":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/3584","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/comments?post=3584"}],"version-history":[{"count":0,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/3584\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/pages\/53"}],"wp:attachment":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/media?parent=3584"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}