{"id":10779,"date":"2026-06-28T08:45:21","date_gmt":"2026-06-28T08:45:21","guid":{"rendered":"https:\/\/cardiocases.com\/?post_type=ecg_case&#038;p=10779"},"modified":"2026-07-02T11:46:33","modified_gmt":"2026-07-02T11:46:33","slug":"trace-1-8-second-degree-av-block","status":"publish","type":"ecg_case","link":"https:\/\/cardiocases.com\/fr\/ecg_case\/trace-1-8-second-degree-av-block\/","title":{"rendered":"Trace 1.8: Second degree AV-block"},"content":{"rendered":"","protected":false},"featured_media":9515,"template":"","ecg_case_type":[250],"language_ecgcase":[258],"class_list":["post-10779","ecg_case","type-ecg_case","status-publish","has-post-thumbnail","hentry","ecg_case_type-atrioventricular-block","language_ecgcase-english"],"acf":{"ecg_case_title":"Trace 1.8: Second degree AV-block","patient_description":"65-year-old man, hospitalized for sudden syncope;","quiz_question":"Which answer(s) is(are) true?","quiz_answer_1":"the ECG shows an atrial bigeminy","quiz_answer_2":"the ECG shows a 2:1 AV block","quiz_answer_3":"the ECG shows a third-degree AV block","quiz_answer_4":"the ECG shows a left bundle branch block","quiz_answer_5":"the ECG shows a right bundle branch block","correct_answer":["B","E"],"ecg_image":10057,"ecg_description":"Regular sinus activity; one out of two P waves is blocked: 2:1 second-degree AV block pattern; wide QRS with left axis: right bundle branch block pattern with left anterior fascicular block;","ecg_info_box":"In 2:1 block, one P wave is conducted and the following wave is blocked. It is difficult to localize the exact location of the block. The analysis of earlier or later tracings may suggest a supra-Hisian block (the presence of Wenckebach periods) or an intra- or infra-Hisian block (presence of a typical Mobitz 2 tracing), with differentiation between the 2 having significant prognostic importance. Electrophysiological study also allows defining the location of the block (supra-Hisian: blocked P wave not followed by a His potential; intra- or infra-Hisian: blocked P wave followed by a His potential).","commentary_ecg":"2-to-1 AV block deserves to be individualized as it is relatively common and represents a border zone between second-degree block and high-grade block since it comprises the same number of blocked waves as conducted P waves. It is difficult to determine the supra-, intra- or infra-Hisian location. The recording of long tracings may reveal a typical Wenckebach pattern with variations in the duration of the PR interval (in favor of a nodal Mobitz 1) or a Mobitz 2 pattern with several conducted P waves followed by a blocked P wave without modification of the PR interval (in favor of an intra- or infra-Hisian block).\r\n\r\nIn a 2:1 AV block, the PR interval of the conducted P waves is typically of normal duration but can be prolonged. Variations can be observed in the PP interval, with PP intervals with QRS complexes being shorter than PP intervals without QRS complexes (ventriculophasic sinus arrhythmia). Different hypotheses have been proposed to explain this alternation in atrial cycles (short PP cycle with QRS, long PP cycle without QRS): 1) ventricular depolarization could promote stretching of the right atrium responsible for an increase in automaticity of the sinus node and a decrease in  PP interval; 2) ventricular depolarization is accompanied by an increase in cardiac output and an effect on baroreceptors, accompanied by a decrease in parasympathetic activation leading to an increase in the sinus rate.\r\n\r\nIn a high-grade block, non-conducting P waves are more numerous than conducted P waves. Atrioventricular conduction can occur at regular (3:1 block, 4:1 block, etc.) or irregular intervals. A junctional or ventricular escape beat is commonly observed causing a transient dissociative pattern with a few rare captures (conducted P waves).\r\n\r\nIn this symptomatic patient, the indication for pacemaker implantation is indisputable (class I indication).","ecg_info_post_answer":"&nbsp;\r\n\r\n<img class=\"alignnone wp-image-10793 size-large\" src=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/06\/trace-1-8-ecg-en-1024x576.jpg\" alt=\"\" width=\"800\" height=\"450\" \/>"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Trace 1.8: Second degree AV-block - Cardiocases<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cardiocases.com\/fr\/ecg_case\/trace-1-8-second-degree-av-block\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Trace 1.8: Second degree AV-block - Cardiocases\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cardiocases.com\/fr\/ecg_case\/trace-1-8-second-degree-av-block\/\" \/>\n<meta property=\"og:site_name\" content=\"Cardiocases\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-02T11:46:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/03\/trace-1-8-ecg.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1\" \/>\n\t<meta property=\"og:image:height\" content=\"1\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/ecg_case\\\/trace-1-8-second-degree-av-block\\\/\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/ecg_case\\\/trace-1-8-second-degree-av-block\\\/\",\"name\":\"Trace 1.8: Second degree AV-block - Cardiocases\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/ecg_case\\\/trace-1-8-second-degree-av-block\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/ecg_case\\\/trace-1-8-second-degree-av-block\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/trace-1-8-ecg.png\",\"datePublished\":\"2026-06-28T08:45:21+00:00\",\"dateModified\":\"2026-07-02T11:46:33+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/ecg_case\\\/trace-1-8-second-degree-av-block\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/cardiocases.com\\\/ecg_case\\\/trace-1-8-second-degree-av-block\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/ecg_case\\\/trace-1-8-second-degree-av-block\\\/#primaryimage\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/trace-1-8-ecg.png\",\"contentUrl\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2026\\\/03\\\/trace-1-8-ecg.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/ecg_case\\\/trace-1-8-second-degree-av-block\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/cardiocases.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Trace 1.8: Second degree AV-block\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#website\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/\",\"name\":\"Cardiocases\",\"description\":\"Real cardiac device traces, pacemaker &amp; ICD learning \u2014 built by electrophysiologists\",\"publisher\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/cardiocases.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#organization\",\"name\":\"Cardiocases\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cardiocases_logo.png\",\"contentUrl\":\"https:\\\/\\\/cardiocases.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/cardiocases_logo.png\",\"width\":1755,\"height\":499,\"caption\":\"Cardiocases\"},\"image\":{\"@id\":\"https:\\\/\\\/cardiocases.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/cardiocases\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Trace 1.8: Second degree AV-block - Cardiocases","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cardiocases.com\/fr\/ecg_case\/trace-1-8-second-degree-av-block\/","og_locale":"fr_FR","og_type":"article","og_title":"Trace 1.8: Second degree AV-block - Cardiocases","og_url":"https:\/\/cardiocases.com\/fr\/ecg_case\/trace-1-8-second-degree-av-block\/","og_site_name":"Cardiocases","article_modified_time":"2026-07-02T11:46:33+00:00","og_image":[{"url":"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/03\/trace-1-8-ecg.png","width":1,"height":1,"type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/cardiocases.com\/ecg_case\/trace-1-8-second-degree-av-block\/","url":"https:\/\/cardiocases.com\/ecg_case\/trace-1-8-second-degree-av-block\/","name":"Trace 1.8: Second degree AV-block - Cardiocases","isPartOf":{"@id":"https:\/\/cardiocases.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cardiocases.com\/ecg_case\/trace-1-8-second-degree-av-block\/#primaryimage"},"image":{"@id":"https:\/\/cardiocases.com\/ecg_case\/trace-1-8-second-degree-av-block\/#primaryimage"},"thumbnailUrl":"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/03\/trace-1-8-ecg.png","datePublished":"2026-06-28T08:45:21+00:00","dateModified":"2026-07-02T11:46:33+00:00","breadcrumb":{"@id":"https:\/\/cardiocases.com\/ecg_case\/trace-1-8-second-degree-av-block\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cardiocases.com\/ecg_case\/trace-1-8-second-degree-av-block\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cardiocases.com\/ecg_case\/trace-1-8-second-degree-av-block\/#primaryimage","url":"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/03\/trace-1-8-ecg.png","contentUrl":"https:\/\/cardiocases.com\/wp-content\/uploads\/2026\/03\/trace-1-8-ecg.png"},{"@type":"BreadcrumbList","@id":"https:\/\/cardiocases.com\/ecg_case\/trace-1-8-second-degree-av-block\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/cardiocases.com\/"},{"@type":"ListItem","position":2,"name":"Trace 1.8: Second degree AV-block"}]},{"@type":"WebSite","@id":"https:\/\/cardiocases.com\/#website","url":"https:\/\/cardiocases.com\/","name":"Cardiocases","description":"Real cardiac device traces, pacemaker &amp; ICD learning \u2014 built by electrophysiologists","publisher":{"@id":"https:\/\/cardiocases.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/cardiocases.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/cardiocases.com\/#organization","name":"Cardiocases","url":"https:\/\/cardiocases.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/","url":"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png","contentUrl":"https:\/\/cardiocases.com\/wp-content\/uploads\/2025\/07\/cardiocases_logo.png","width":1755,"height":499,"caption":"Cardiocases"},"image":{"@id":"https:\/\/cardiocases.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/cardiocases\/"]}]}},"_links":{"self":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/ecg_case\/10779","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/ecg_case"}],"about":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/types\/ecg_case"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/media\/9515"}],"wp:attachment":[{"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/media?parent=10779"}],"wp:term":[{"taxonomy":"ecg_case_type","embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/ecg_case_type?post=10779"},{"taxonomy":"language_ecgcase","embeddable":true,"href":"https:\/\/cardiocases.com\/fr\/wp-json\/wp\/v2\/language_ecgcase?post=10779"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}